Appendix
A.3 Parameters
p2503[0]
LR length unit MU per 10 mm
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: mm
 
Min:
0.000001 [mm]
Description:
Sets the length unit MU per 10 mm set by the user.
For a linear scale, this establishes a reference between the physical arrangement and the neutral length units LU used
in the drive.
Example, linear scale:
p2503 = 10000 means: 10 mm should be resolved to µm (this means that 1 LU = 1 µm).
Note
When selecting a physical length unit, the drive automatically preassigns the parameter and it cannot be changed.
The assignment to the grid spacing can be achieved using this for a rotary axis with linear encoder.
MU: measurement unit
p2503[0]
LR length unit MU per 10 mm
S200 Basic PN (EPOS
Data type: FloatingPoint32
Lastseite rotierend),
Read permission:
S200 PN (EPOS
Write permission:
Lastseite rotierend)
Can be changed in the operating
state:
Parameter group:
 
Unit: °
 
Min:
0.000001 [°]
Description:
Sets the length unit MU per 10 mm set by the user.
For a linear scale, this establishes a reference between the physical arrangement and the neutral length units LU used
in the drive.
Example, linear scale:
p2503 = 10000 means: 10 mm should be resolved to µm (this means that 1 LU = 1 µm).
Note
When selecting a physical length unit, the drive automatically preassigns the parameter and it cannot be changed.
The assignment to the grid spacing can be achieved using this for a rotary axis with linear encoder.
MU: measurement unit
p2504[0]
LR motor/load motor revolutions
 
Data type: Unsigned32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
1
772
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Commissioning
Position control
Max:
2.1474837e+09 [mm]
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Commissioning
Position control
Max:
2.1474837e+09 [°]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Commissioning
Position control, Mechanics
Max:
1048576
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
 
Factory setting:
10.000000 [mm]
 
Factory setting:
10.000000 [°]
 
Factory setting:
1