Procedure
Replacing a device via the project tree
Proceed as follows to replace the current device via the project tree:
1. In the project tree, select the converter to be replaced. Open context menu "Change device".
The corresponding dialog box opens.
Figure 8-3
Changing the device via the project tree
The data of the current converter are displayed on the top left. At the top right, the
replacement devices that are applicable are displayed in a hardware catalog.
2. Select the replacement device required in the hardware catalog of the dialog box.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
8.5 Combining and configuring devices in the project
Commissioning (Startdrive)
237