Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 450

Servo drive system
Table of Contents

Advertisement

System messages
12.3 Faults and alarms
Component:
Control Unit (CU)
Response:
OFF2
Acknowledgment: IMMEDIATELY
Cause:
At least one system overload has been identified.
Fault value (r0949, interpret decimal):
1: Computing time load too high.
5: Peak load too high.
Note:
As long as this fault is present, it is not possible to save the parameters (p0977).
Remedy:
- Reduce the computing time load of the drive unit to below 100 %.
- Deactivate functions.
- Deactivate drive objects.
- Remove drive objects from the target topology.
- Note the DRIVE-CLiQ topology rules and if required, change the DRIVE-CLiQ topology.
F01068
CU: Data memory memory overflow
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
%1
Component:
Control Unit (CU)
Response:
OFF2
Acknowledgment: IMMEDIATELY
Cause:
The utilization for a data memory area is too large.
Fault value (r0949, interpret binary):
Bit 0 = 1: High-speed data memory 1 overloaded
Bit 1 = 1: High-speed data memory 2 overloaded
Bit 2 = 1: High-speed data memory 3 overloaded
Bit 3 = 1: High-speed data memory 4 overloaded
Remedy:
- Deactivate function.
- Deactivate drive object.
- Remove drive object from the target topology.
A01069
Parameter backup and device incompatible
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
Control Unit (CU)
Response:
NONE
Acknowledgment: NONE
Cause:
The parameter backup on the memory card and the drive unit do not match.
The module boots with the factory settings.
Example:
Devices A and B. are not compatible and a memory card with the parameter backup for device A is inserted in device B.
Remedy:
- Insert a memory card with compatible parameter backup and carry out a POWER ON.
- Insert a memory card without parameter backup and carry out a POWER ON.
- Save the parameters (p0977 = 1).
F01070
Project/firmware is being downloaded to the memory card
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
%1
Component:
Control Unit (CU)
Response:
OFF2
448
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2