c2578
EPOS negative software limit switch
S200 Basic PN (EPOS
Data type: FloatingPoint32
Lastseite rotierend),
Read permission:
S200 PN (EPOS
Write permission:
Lastseite rotierend)
Parameter group:
Unit: °
Description:
Signal for the negative software limit switch.
Dependency:
See also: c2579, p2580, p2581, c2582
NOTICE
A change to the software limit switch immediately becomes effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note
The following applies for the setting of the software limit switch:
Negative software limit switch < positive software limit switch
c2579
EPOS positive software limit switch
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: mm
Description:
Signal for the positive setpoint limit switch.
Dependency:
See also: c2578, p2580, p2581, c2582
NOTICE
A change to the software limit switch immediately becomes effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note
The following applies for the setting of the software limit switch:
Negative software limit switch < positive software limit switch
c2579
EPOS positive software limit switch
S200 Basic PN (EPOS
Data type: FloatingPoint32
Lastseite rotierend),
Read permission:
S200 PN (EPOS
Write permission:
Lastseite rotierend)
Parameter group:
Unit: °
Description:
Signal for the positive setpoint limit switch.
Dependency:
See also: c2578, p2580, p2581, c2582
NOTICE
A change to the software limit switch immediately becomes effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note
The following applies for the setting of the software limit switch:
Negative software limit switch < positive software limit switch
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Limit
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Limit
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Limit