Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 852

Servo drive system
Table of Contents

Advertisement

Appendix
A.3 Parameters
Note
The time in r8400 and r8401 is used to display the fault and alarm times.
Possible date/time setting:
- Web server (manually)
- NTP (Network Time Protocol)
When the converter is switched off, date/time are not updated.
After the converter has restarted, the date and time that the converter was in a no-current condition applies.
r8401[0...2]
Time
 
Data type: Unsigned16
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Displays the current time in hours, minutes and seconds.
Index:
[0] = Hour (0 ... 23)
[1] = Minute (0 ... 59)
[2] = Second (0 ... 59)
Note
The time in r8400 and r8401 is used to display the fault and alarm times.
The time is displayed in the 24-hour format.
Possible date/time setting:
- Web server (manually)
- NTP (Network Time Protocol)
When the converter is switched off, date/time are not updated. After power on the instant of the previous power off is
valid.
r8600[0...20]
PROFIdrive PZD receive Float32
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Displays the PZD (setpoints) in the Float32 format received from the fieldbus controller.
850
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Diagnostics general
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Configuration
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
 
 