Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 699

Servo drive system
Table of Contents

Advertisement

r0026
DC link voltage smoothed
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: V
Description:
Displays the smoothed actual value of the DC link voltage.
Dependency:
See also: r0070
NOTICE
This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the unsmoothed
value should be used.
Note
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The DC link voltage is available smoothed (r0026) and unsmoothed (r0070).
r0027
Absolute actual current smoothed
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: Arms
Description:
Displays the smoothed absolute current actual value.
Dependency:
See also: r0068
NOTICE
This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the unsmoothed
value should be used.
Note
A_INF, S_INF, VECTOR: Smoothing time constant = 300 ms
SERVO: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
r0031
Actual torque smoothed
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: Nm
Description:
Displays the smoothed torque actual value.
Dependency:
See also: r0080
Note
Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The torque actual value is available smoothed (r0031) and unsmoothed (r0080).
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Brake control, Mode signals / displays
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Mode signals / displays, Power unit
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Brake control, Mode signals / displays