Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 767

Servo drive system
Table of Contents

Advertisement

r2139.0...15
Status word faults/alarms 1
 
Data type: Unsigned16
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Displays status word 1 of faults and alarms.
Bit array:
Bit
 
00
 
01
 
03
 
05
 
07
 
11
 
12
 
13
 
14
 
15
Note
For bit 03, 05, 07:
These bits are set if at least one fault/alarm or safety message occurs. The entry in the fault/alarm buffer or safety
message buffer is delayed. This is the reason that the fault/alarm buffer or safety message buffer should only be read if,
after "Fault active", "Alarm active" or "Safety message active" occurs, a change is also identified in the buffer (r0944,
r2121, r60044).
For bits 11, 12:
These status bits are used for the classification of internal alarm classes and are intended for diagnostic purposes only
on certain automation systems with integrated SINAMICS functionality.
r2145[0...63]
Alarm time received in days
 
Data type: Unsigned16
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Displays the system runtime in days when the alarm occurred.
Dependency:
See also: r2114, r2122, r2123, r2124, r2125, r2134, r2146, r3123
NOTICE
The time comprises r2145 (days) and r2123 (milliseconds).
Note
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2146[0...63]
Alarm time cleared in days
 
Data type: Unsigned16
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Displays the system runtime in days when the alarm was cleared.
Dependency:
See also: r2114, r2122, r2123, r2124, r2125, r2134, r2145, r3123
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Signal name
Being acknowledged
Acknowledgment required
Fault present
Safety message present
Alarm present
Alarm class bit 0
Alarm class bit 1
Maintenance required
Maintenance urgently required
Fault gone/can be acknowledged
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Faults / alarms
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Faults / alarms
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Faults / alarms
A.3 Parameters
 
1 signal
0 signal
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
High
Low
High
Low
Yes
No
Yes
No
Yes
No
 
 
Appendix
 
 
 
 
 
 
 
 
 
 
 
765