r10080.0...7
SI status signals channel A
S200 PN
Data type: Unsigned32
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Status signals (channel A) for safety-relevant motion monitoring functions integrated in the drive.
Bit array:
Bit
 
00
 
07
NOTICE
For bit 07:
An internal event is displayed if STO is active.
r10098
SI actual checksum across device-specific parameters
S200 PN
Data type: Unsigned32
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Displays the checksum over the checksum-checked parameters for the device-specific parameters of the drive system
(actual checksum).
Dependency:
See also: p10099
p10099
SI reference checksum across device-specific parameters
S200 PN
Data type: Unsigned32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0000 hex
Description:
Displays the checksum over the checksum-checked parameters for the device-specific parameters of the drive system
(reference checksum).
Dependency:
See also: r10098
r10151.0
SI digital inputs status channel B
S200 PN
Data type: Unsigned8
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Display for the single-channel, logical and debounced status of the failsafe digital inputs of channel B.
Bit array:
Bit
 
00
Dependency:
See also: p10017, p10040
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Signal name
STO or safe pulse cancellation active
Internal event
Signal name
Status of DI 11+ (X131.5/6)
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
 
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Basic functions
Visible in: Extended display
Read drive data or acknowledge messages
Edit Safety Integrated application
Commissioning (Safety Integrated)
Basic functions
Max:
FFFF FFFF hex
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
 
A.3 Parameters
 
1 signal
0 signal
Yes
No
No
Yes
 
 
Factory setting:
A1A1 A1A1 hex
 
1 signal
0 signal
Logical 1
Logical 0