Note
Modified parameters are displayed in indices 0 to 298. If an index contains the value 0, then the list ends here. In a long
list, index 299 contains the parameter number at which position the list continues.
This list consists solely of the following parameters:
r0980[0...299], r0981[0...299] ... r0989[0...299]
The parameters in this list are not displayed in the parameter lists of the commissioning tool. However, they can be read
from a higher-level control system (e.g. PROFIBUS master).
p1082[0]
Maximum speed
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: rpm
 
Min:
0.000 [rpm]
Description:
Sets the maximum motor speed to a value less than or equal to the maximum motor speed (p0322).
The set value is valid for both directions of rotation.
Dependency:
See also: p0322
p1083[0]
Speed limit in positive direction of rotation
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: rpm
 
Min:
0.000 [rpm]
Description:
Sets the maximum speed for the positive direction.
p1086[0]
Speed limit in negative direction of rotation
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: rpm
 
Min:
-210000.000 [rpm]
Description:
Sets the speed limit for the negative direction.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Ready for operation
Motorized potentiometer, Speed limiting, U/f control, Speed controller, Quick
commissioning
Max:
210000.000 [rpm]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Speed limiting, U/f control, Speed controller
Max:
210000.000 [rpm]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Speed limiting, U/f control, Speed controller
Max:
0.000 [rpm]
A.3 Parameters
 
Factory setting:
1500.000 [rpm]
 
Factory setting:
210000.000 [rpm]
 
Factory setting:
-210000.000 [rpm]