p2599
EPOS home position value
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: mm
 
Min:
-2.1474828e+09 [mm]
Description:
Sets the position value for the home position.
This value is set as the actual axis position after homing or adjustment.
Dependency:
See also: p2507, c2595, c2596, c2597, c2598
p2599
EPOS home position value
S200 Basic PN (EPOS
Data type: FloatingPoint32
Lastseite rotierend),
Read permission:
S200 PN (EPOS
Write permission:
Lastseite rotierend)
Can be changed in the operating
state:
Parameter group:
 
Unit: °
 
Min:
-2.1474828e+09 [°]
Description:
Sets the position value for the home position.
This value is set as the actual axis position after homing or adjustment.
Dependency:
See also: p2507, c2595, c2596, c2597, c2598
p2600
EPOS active homing home position offset
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: mm
 
Min:
-2.1474828e+09 [mm]
Description:
Sets the home position shift for active homing.
Dependency:
See also: c2598
p2600
EPOS active homing home position offset
S200 Basic PN (EPOS
Data type: FloatingPoint32
Lastseite rotierend),
Read permission:
S200 PN (EPOS
Write permission:
Lastseite rotierend)
Can be changed in the operating
state:
Parameter group:
 
Unit: °
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Homing
Max:
2.1474828e+09 [mm]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Homing
Max:
2.1474828e+09 [°]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Homing
Max:
2.1474828e+09 [mm]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Homing
A.3 Parameters
 
Factory setting:
0.0000 [mm]
 
Factory setting:
0.0000 [°]
 
Factory setting:
0.0000 [mm]
 
Appendix