02
03
Dependency:
The simulation of a digital input is selected using p0795.
See also: p0795
Note
This parameter is not saved when backing up data (p0977).
DI: Digital Input
c0849[0]
No Quick Stop / Quick Stop (OFF3)
Data type: Unsigned8
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Second signal for command "No Quick Stop / Quick Stop (OFF3)"
The following signals are AND'ed:
- c0848 "No Quick Stop / Quick Stop (OFF3) signal 1"
- c0849 "No Quick Stop / Quick Stop (OFF3) signal 2"
For the PROFIdrive profile, the result of the AND logic operation corresponds to control word 1 bit 2 (STW1.2).
c0848 = 0 signal or c0849 = 0 signal
- OFF3 (braking along the OFF3 ramp (p1135), then pulse cancellation and switching on inhibited)
c0848 = 1 signal or c0849 = 1 signal
- No OFF3 (enable is possible)
CAUTION
When "master control from PC" is activated, then this binary signal sink is effective.
Note
For drives with closed-loop torque control (activated using c1501), the following applies:
0 signal:
- No dedicated braking response, but pulse cancellation when standstill is detected (p1226, p1227).
r0898.0...14
Control word sequence control
Data type: Unsigned16
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Display and numerical signal source for the control word of the sequence control.
Bit array:
Bit
00
01
02
03
04
05
06
07
10
12
14
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
DI 2 (X130.3)
DI 3 (X130.4)
Signal name
ON/OFF1
Operating condition / OFF2
Operating condition / OFF3
Enable operation
Enable ramp-function generator
Continue ramp-function generator
Enable speed setpoint
Command open brake
Master control by PLC
Enable speed controller
Command close brake
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Shutdown functions, Drive enable signals
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Control/status words
A.3 Parameters
High
Low
High
Low
1 signal
0 signal
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Appendix
723