A.3 Parameters
 
13
 
14
 
15
Note
For bit 03 ... 00:
Bit 3, 2, 1, 0 = 0, 0, 0, 0 --> component not available.
Bit 3, 2, 1, 0 = 0, 0, 0, 1 --> run up, acyclic communications (LED = orange).
Bit 3, 2, 1, 0 = 0, 0, 1, 0 --> operating mode, cyclic communications (LED = green).
Bit 3, 2, 1, 0 = 0, 0, 1, 1 --> alarm (LED = green).
Bit 3, 2, 1, 0 = 0, 1, 0, 0 --> fault (LED = red).
Bit 3, 2, 1, 0 = 0, 1, 0, 1 --> detection via LED and operating mode (LED = green/orange).
Bit 3, 2, 1, 0 = 0, 1, 1, 0 --> detection via LED and alarm (LED = green/orange).
Bit 3, 2, 1, 0 = 0, 1, 1, 1 --> detection via LED and fault (LED = red/orange).
Bit 3, 2, 1, 0 = 1, 0, 0, 0 --> firmware being downloaded (LED = green/red with 0.5 Hz).
Bit 3, 2, 1, 0 = 1, 0, 0, 1 --> firmware download completed, wait for POWER ON (LED = green/red with 2.0 Hz).
For bits 12 ... 11:
These status bits are used for the classification of internal alarm classes and are intended for diagnostic purposes only
on certain automation systems with integrated SINAMICS functionality.
p0201[0]
Power unit code number
 
Data type: Unsigned16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Sets the actual code number of the power unit being used.
p0210
Device supply voltage
 
Data type: Unsigned16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: V
 
Min:
1 [V]
Description:
Sets the device supply voltage.
The voltage between two phases should be entered as the device supply voltage.
This setting is important for operating with voltages that are less than the voltage range for which the drive is designed.
Note
Setting ranges for p0210 as a function of the rated power unit voltage:
U_rated = 230 V:
- p0210 = 200 ... 240 V
U_rated = 400 V:
- p0210 = 380 ... 480 V (wide voltage range, in addition to 200 ... 240 V)
706
Maintenance required
Maintenance urgently required
Fault gone/can be acknowledged
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Commissioning
Power unit
Max:
65535
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Ready for operation
Power unit, Quick commissioning
Max:
63000 [V]
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Yes
No
Yes
No
Yes
No
 
Factory setting:
0
 
Factory setting:
400 [V]
 
 
 