Restoring The Drive Data Via The Web Server - Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual

Servo drive system
Table of Contents

Advertisement

13.1.3.1

Restoring the drive data via the web server

Requirement
• The converter is operated without an SD card.
• You have a backup file of the source converter on your operating unit.
In the description below, a distinction is made between restoring drive data from an
encrypted backup file or from an unencrypted backup file.
• The rated power of the target converter is the same as the rated power of the converter from
which the backed-up data and settings originate.
• Ideally, the target converter is in the factory setting.
It either involves a brand-new target converter or a target converter where all user-defined
settings have been restored to the factory setting. You can find more information in Section
"Reset of all user-defined settings to the factory setting via an SD card (Page 587)".
Procedure
1. Switch off the supply voltage of the source converter.
2. Release all of the connections at the source converter, replace the converter and re-establish
the connections at the target converter.
3. Switch on the supply voltage of the target converter.
4. Enter the IP address of the target converter, e.g. https://169.254.11.22, in the web browser.
The web server is started. The "Basic settings" page is displayed.
5. Make the basic settings for the converter.
You can find more information in Section "Basic settings (Page 173)".
6. Click "Next".
The "Welcome to the Security Wizard" page is displayed.
7. Select the option "Exit the Security Wizard and continue with low security settings".
8. Call the "Backup and restore" menu.
9. Click the "Click to select file, or drag and drop file here" button to select the backup file.
10.To restore the drive data, proceed as described below depending on the specific application.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
13.1 Service and maintenance for the converter
Corrective maintenance
593

Advertisement

Table of Contents
loading