Technical data
14.1
Technical data of the converter
14.1.1
Permissible environmental conditions for the converter
Technical data
Table 14-1
Environmental conditions
Property
Environmental conditions for transport in the transport packaging
Climatic environmental conditions
Mechanical environmental conditions
Protection against chemical substances
Biological environmental conditions
Environmental conditions for long-term storage in the product packaging
Climatic environmental conditions
Mechanical environmental conditions
Protection against chemical substances
Biological environmental conditions
Environmental conditions in operation
Installation altitude
Climatic environmental conditions
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Description
Surrounding air temperature: -40 °C ... +70 °C
Suitable according to Class 2K4 to IEC 60721‑3‑2
Humidity: Max. 95% at 45 °C according to IEC 60721‑3‑2
Vibration:
2 Hz ... 9 Hz: 7.5 mm deflection
9 Hz ... 200 Hz: 2 g vibration
Vibrations permissible according to Class 2M3 to IEC 60721-3-2
Protected according to Class 2C2 to IEC 60721-3-2
Suitable according to Class 2B2 to IEC 60721-3-2
Surrounding air temperature: -40 °C ... +70 °C
Relative humidity: Max. 95%, condensation not permissible
Vibrations permissible according to Class 1M2 to IEC 60721-3-1
Protected according to Class 1C2 to IEC 60721-3-1
Suitable according to Class 1B2 to IEC 60721-3-1
Up to 2000 m above sea level without power derating
Up to 4000 m with power derating
Surrounding air temperature: 0 °C ... 55 °C, > 45 °C with power
derating
Relative humidity: Max. 95%, condensation not permissible