8.7.2.1
Configuring a measuring probe using the technology objects
Requirement
• The project includes a control system, and is connected to the converter.
• A technology object "PositioningAxis_1" is created for the control system and is active.
Procedure
Proceed as follows to use a measuring input:
1. In the project navigation, expand the follow entries in the order specified below:
–
–
–
The "Add new measuring input" entry is displayed.
2. Double-click the "Add new measuring input" entry
A new measuring input is created and additional functions are displayed.
3. Double-click the "Configuration" entry
The corresponding screen form opens in the device view.
4. Click the "Hardware interface" option
The corresponding screen form opens.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Technology objects
PositioningAxis_1
Measuring inputs
①
.
②
.
③
in the secondary navigation.
Commissioning (Startdrive)
8.7 Configuring the converter
279