Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 815

Servo drive system
Table of Contents

Advertisement

p2619[0...n]
EPOS traversing block acceleration override
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: %
 
Min:
1.0 [%]
Description:
Sets the acceleration override for the traversing block.
The override refers to the maximum acceleration (p2572).
Dependency:
The number of indices depends on p2615.
See also: p2572, p2615, p2616, p2617, p2618, p2620, p2621, p2622, p2623
p2620[0...n]
EPOS traversing deceleration override
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: %
 
Min:
1.0 [%]
Description:
Sets the deceleration override for the traversing block.
The override refers to the maximum deceleration (p2573).
Dependency:
The number of indices depends on p2615.
See also: p2573, p2615, p2616, p2617, p2618, p2619, p2621, p2622, p2623
NOTICE
If, when calculating the traversing profile, it is identified that the target position of the next block with the programmed
deceleration override will not be reached without direction reversal (flying block change), then the old (actual)
deceleration override remains effective.
p2621[0...n]
EPOS traversing block task
 
Data type: Integer16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
1
Description:
Sets the required task for the traversing block.
Value:
1:
 
2:
 
3:
 
4:
 
5:
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Traversing blocks
Max:
100.0 [%]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Traversing blocks
Max:
100.0 [%]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Traversing blocks
Max:
9
POSITIONING
FIXED STOP
ENDLESS_POS
ENDLESS_NEG
WAITING
A.3 Parameters
 
Factory setting:
100.0 [%]
 
Factory setting:
100.0 [%]
 
Factory setting:
1
Appendix