12.3 Faults and alarms
F07475
EPOS: Target position < start of traversing range
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
OFF1
Acknowledgment: IMMEDIATELY
Cause:
The target position for relative traversing lies outside the traversing range.
Remedy:
Correct the target position.
F07476
EPOS: Target position > end of the traversing range
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
OFF1
Acknowledgment: IMMEDIATELY
Cause:
The target position for relative traversing lies outside the traversing range.
Remedy:
Correct the target position.
A07477
EPOS: Target position < negative software limit switch
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
In the actual traversing operation, the target position is less than the negative software limit switch.
Remedy:
- Correct the target position.
- Change the negative software limit switch (c2578, p2580).
See also: c2578 (EPOS negative software limit switch), p2580 (EPOS negative software limit switch), c2582 (EPOS software
limit switch activation)
A07478
EPOS: Target position > positive software limit switch
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
In the actual traversing operation, the target position is greater than the positive software limit switch.
Remedy:
- Correct the target position.
- Change the positive software limit switch (c2579, p2581).
See also: c2579 (EPOS positive software limit switch), p2581 (EPOS positive software limit switch), c2582 (EPOS software
limit switch activation)
A07479
EPOS: Negative software limit switch reached
Message class:
Application/technological function faulted (17)
Message value:
-
Component:
None
Response:
NONE
Acknowledgment: NONE
Cause:
The axis is at the position of the negative software limit switch. An active traversing block was interrupted.
520
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB