Description:
Displays the identification of the converter. The drive internally comprises components, device and converter. Both
components require their own identification parameters according to PROFIdrive.
Index:
[0] = Company (Siemens = 42)
[1] = Converter type
[2] = Firmware version
[3] = Firmware date (year)
[4] = Firmware date (day/month)
[5] = PROFIdrive converter type class
[6] = PROFIdrive converter subtype class
[7] = Reserved
[8] = Reserved
[9] = Reserved
[10] = Firmware patch/hot fix
Dependency:
See also: r0964
Note
Example:
r0975[0] = 42 --> SIEMENS
r0975[1] = 311 --> SERVO converter type
r0975[2] = 602 --> first part firmware version V06.02 (second part refer to index 10)
r0975[3] = 2023 --> year 2023
r0975[4] = 1706 --> 17th of June
r0975[5] = 1 --> PROFIdrive type class = 1 (axis)
r0975[6] = 8 --> PROFIdrive subtype class = 4 (application class)
r0975[7] = 1 --> 1 (fixed value)
r0975[8] = 0 (reserved)
r0975[9] = 0 (reserved)
r0975[10] = 0 --> second part firmware version (complete version: V06.02.00.00)
p0976
Reset all parameters
 
Data type: Unsigned16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Resets all drive system parameters to the factory settings.
Value:
0:
 
1:
NOTICE
Writing to parameters is inhibited during the reset operation.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Ready for operation
Save & reset
Max:
1
Inactive
Start to reset all parameters
A.3 Parameters
 
Factory setting:
0
Appendix
731