Note
To be observed for devices used in Category C3
In a residential environment this product may cause radio-frequency interference.
• Do not use this device in the first environment (residential area).
Note
Complying with Category C2 interference emission
When using a cable of more than 3 m to connect the converter to the PROFINET or Ethernet
interface, electromagnetic interferences may occur. Use appropriate ferrite clamps, cabinet
feedthrough, or fiber optic transceivers to minimize the interference emission.
Note
The conducted and radiated emissions of the PROFINET ports are in compliance with the
standards of IEC 61800‑6‑8, Class A (CISPR 32), and IEC 61800‑3 Category C3.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Application planning
4.8 EMC-compliant installation
97