Technical data
14.1 Technical data of the converter
Parameter
 
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be
1)
provided in accordance with the National Electrical Code and any additional local codes.
2)
The 200 V converter has an overvoltage threshold of 410 V DC and an undervoltage threshold of 155 V DC; the 400 V
converter has an overvoltage threshold of 820 V DC and undervoltage threshold of 320 V DC.
Motor temperature is calculated by motor thermal model and protected by the output current from the converter.
3)
To comply with permissible line harmonics, depending on the line connection conditions, different values may be required.
4)
5)
The maximum permissible short-circuit current for 200 V variants with Type E Combination Motor Controllers is 65 kA.
When the converter works with a motor with a brake, the voltage tolerance of 24 V DC power supply must be -5% to +20%
6)
to meet the voltage requirement of the brake.
14.1.3
Specific data of the 200 V converters
Technical data
Table 14-3
Specific technical data of the 200 V converters frame size A
Article No. 6SL5☐10-1BB
Frame size
Rated input current (A) 1 AC
Rated output current (A)
Maximum output current (A)
Maximum supported motor power (kW)
Power loss (W)
612
Description
STO fulfills the requirements of the following standards:
Response time: ≤ 20 ms
The response time of the Safe Torque Off function is the time between
selecting the function and the function becoming active.
Probability of Failure per Hour (PFH): < 10
Failure probabilities must be specified for Safety Integrated Functions in the
form of a PFH value according to IEC 61800-5-2, IEC 62061 and
EN ISO 13849-1. The PFH value of a Safety Integrated Function depends on
the safety concept of the converter, its hardware configuration and the PFH
values of the other components used for the Safety Integrated Function.
Mission time: 20 years
You may not operate converters with integrated safety functions for longer
than the mission time. The mission time starts when the device is delivered.
The mission time cannot be extended. This is the case even if a service
department checks the converter – or in the meantime, the converter was
decommissioned.
3 AC
SIL 3 according to IEC 61800-5-2
PL e according to ISO 13849-1
Category 4 according to ISO 13849‑1
10-1AF0
FSA
1.2
0.6
0.81
3.3
0.1
12
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
-7
10-2AF0
FSA
2.0
1.1
1.33
5.1
0.2
15