Commissioning (Startdrive)
8.6 Carrying out guided quick startup
In quick startup step "Telegrams", you can optimize these default settings if this is necessary
for your drive.
Requirement
• The motor used in the device configuration of the drive has been completely specified and
configured.
• Optionally, a controller (PLC) can also be created in the device configuration and networked
with the drive.
• There is no active online connection between the drive and operating unit.
Telegrams can only be configured offline.
• For activated user management (UMAC):
The function rights for configuring in the quick startup are activated for your user role.
Details on this topic are provided in Chapter "Security settings in Startdrive" of Industrial
Cybersecurity Configuration Manual
109810578).
Procedure
Proceed as follows to configure the telegrams:
1. Select the desired standard telegram from the "Telegram" drop-down list.
2. Correct the preset reference speed in the field with the same name.
3. Click
configuration.
The properties of the PROFINET interface are displayed in the inspector window. Make the
required settings under "Telegram settings (Page 286)".
4. Switch back to the quick startup step "Telegrams".
5. Click "Next" to display the next quick startup step.
Result
The telegrams for communication are configured.