Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 795

Servo drive system
Table of Contents

Advertisement

Note
The jerk limiting is internally converted into a jerk time as follows:
Jerk time Tr = max(p2572, p2573) / p2574
The jerk time is internally limited to 1000 ms, and is rounded off to an integer multiple of the sampling time of the basic
positioner cycle.
The jerk time is the same for the acceleration and deceleration phases, also if the maximum acceleration (p2572) and
maximum deceleration (p2573) are set differently.
If the maximum acceleration and maximum deceleration are set differently, then motion is not optimal from a time
perspective as the jerk limit cannot be utilized for the lower of the two values.
If, in the traversing profile, the acceleration time without jerk limiting is shorter than jerk time Tr, then motion with jerk
limiting is not time-optimized.
For traversing motion with a direct transition between acceleration and deceleration (i.e. jerk time is greater than the
constant velocity phase), jerk can increase up to twice the parameterized jerk.
CONTINUE_FLYING with direction reversal acts internally just like a CONTINUE_WITH_STOP without the "Set position
reached" being set. Without jerk limiting, this behavior can hardly be noticed as, when reversing, the position setpoint
is only kept at zero for the duration of one interpolator clock cycle.
For block change enable CONTINUE_WITH_STOP, jerk limiting results in a longer delay time.
c2575
EPOS jerk limiting activation
 
Data type: Unsigned8
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Signal to activate jerk limiting.
Activating/deactivating:
- Using c2575 = 1 signal or 0 signal.
- Using the JERK command in the traversing block (only for c2575 = 0 signal).
Dependency:
See also: p2574
Note
A change to the signal state is only accepted at zero speed.
p2576
EPOS modulo correction modulo range
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: mm
 
Min:
0.0001 [mm]
Description:
Sets the modulo range for axes with modulo correction.
Dependency:
See also: c2577
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Limit, Jog, Homing, Traversing blocks, Direct setpoint input (MDI)
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Ready for operation
Basic positioner, Mechanics, Actual position value preprocessing
Max:
2.1474828e+09 [mm]
A.3 Parameters
 
 
Factory setting:
360.0000 [mm]
Appendix
793

Advertisement

Table of Contents
loading

Table of Contents