Commissioning (web server)
7.4 Functions and menus
Commissioning involves the following steps:
• Basic settings:
If the converter has already been commissioned, then the web server jumps to the basic
settings.
The following settings are required for a brand-new converter:
– Language, date, time
• Security settings:
The settings are configured with the help of the Security Wizard.
You can find more information in Section "Security settings (Page 174)".

• Quick setup:

Menu "Commissioning" > "Quick setup"
– Entry or checking of motor and encoder data
– Limit values and I/O configuration
• Optimize motor:
Menu "Commissioning" > "Optimization"
The Optimization function measures the mechanical drive train using short test signals and
adapts the controller parameters to the mechanics installed.
• Test motor operation:
Action bar > "Control panel"
Test of motor operation using the control panel in jog mode or continuous operation
• Backup:
Menu "Backup and restore"
Siemens recommends a backup of the drive settings after commissioning.
More information
For more information about user management and security settings, see the Configuration
Manual Industrial Cybersecurity Configuration Manual
support.industry.siemens.com/cs/ww/en/view/109810578).
7.4.2.2
Quick setup
Overview
The converter can generally be operated without making additional settings using quick setup.
Siemens recommends that quick setup is performed to set the limit values and the I/O
configuration to optimally address the target application.
Requirement
• The drive system has been configured. The components are wired.
• Web server access is active.
180
(https://
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB