A30259
Braking resistor value too low
Message class:
Braking Module faulted (14)
Message value:
%1
Component:
Power Unit
Response:
NONE
Acknowledgment: NONE
Cause:
The braking resistor value used in p0216 is too low.
This can result in an excessively high braking current.
 
Alarm value (r2124, interpret decimal):
Minimum limit value of the braking resistor [0.1 Ohm]
See also: p0216 (Braking resistance value)
Remedy:
- Use a braking resistor with the appropriate resistance value
- Observe the product documentation
F30260
Power unit: Fault in the driver supply for the power semiconductor
Message class:
Hardware/software error (1)
Message value:
-
Component:
Power Unit
Response:
OFF2
Acknowledgment: IMMEDIATELY
Cause:
A fault has occurred in the driver supply of the power semiconductor.
Remedy:
There is a hardware defect. The device must be replaced.
F30262
Power unit: Braking chopper defective
Message class:
Power electronics faulted (5)
Message value:
-
Component:
Power Unit
Response:
OFF2
Acknowledgment: IMMEDIATELY
Cause:
The braking chopper is defective.
Remedy:
Replace the converter.
F30263
Power unit: Braking chopper upper defective
Message class:
Power electronics faulted (5)
Message value:
-
Component:
Power Unit
Response:
OFF2
Acknowledgment: IMMEDIATELY
Cause:
The upper braking chopper is defective.
Remedy:
Replace the converter.
F30264
Power unit: Braking chopper inhibited due to implausible DC link voltage
Message class:
Braking Module faulted (14)
Message value:
%1
Component:
Power Unit
Response:
OFF2
Acknowledgment: IMMEDIATELY
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2