Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 613

Servo drive system
Table of Contents

Advertisement

Parameter
Cooling type
Degree of protection according to IEC 60529
Mains supply
Permissible mains supply network
Line voltage
Line frequency (Hz)
Permissible line voltage fluctuation
Permissible line frequency fluctuation
24 V DC power supply
Voltage (V)
Permissible voltage fluctuation (V)
Maximum current (A)
Safety insulation class
Inputs and outputs
Digital inputs
Digital outputs
Pulse train output (for S200 PN only)
Safety Integrated (for S200 PN only)
Safety function
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Description
For 200 V variants: Natural cooling
For 400 V variants:
– FSA and FSB: Natural cooling
– FSC and FSD: Fan cooling
IP20
TN, TT, IT
1 AC/3 AC 200 V ... 240  V
3 AC 380 V ... 480 V
50/60
-15% ... +10%
-10% ... +10%
24 (-15% ... +20%)
6)
When using a motor without brake: 20.4 ... 28.8
When using a motor with brake: 22.8 ... 28.8
For 200 V variants:
– When using a motor without a brake: 1.2
– When using a motor with a brake: 2.2
For 400 V variants:
– When using a motor without a brake: 1.2
– When using a motor with a brake: 3.2
SELV
Maximum input current: 4 mA (for "1" signal: > 1.5 mA)
General delay time:
– DI 0 → 1: < 10 μs
– DI 1 → 0: < 150 μs
Fast digital input delay time:
– F-DI 0 → 1: < 5 μs
– F-DI 1 → 0: < 5 μs
Maximum output current: 100 mA
Delay time: < 2 ms
Output voltage: line driver (5 V differential)
Output frequency: ≤ 4 MHz
STO, SIL 3 / PL e / Category 4
Technical data
14.1 Technical data of the converter
611

Advertisement

Table of Contents
loading

Table of Contents