Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 727

Servo drive system
Table of Contents

Advertisement

r0922
PROFIdrive PZD telegram selection
S200 Basic PN
Data type: Unsigned16
(Interpolator für EPOS),
Read permission:
S200 PN (Interpolator
Write permission:
für EPOS)
Parameter group:
Unit: -
Description:
Displays the PROFIdrive telegram.
Value:
7:
 
9:
 
111:
 
112:
Note
The telegram is set in the commissioning tool or by the control.
r0924[0...1]
ZSW bit pulses enabled
 
Data type: Unsigned16
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Displays the position of the "Pulses enabled" status signal in the PROFIdrive telegram.
Index:
[0] = Signal number
[1] = Bit position
p0925
PROFIdrive clock synchronous sign-of-life tolerance
 
Data type: Unsigned16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Sets the number of tolerated consecutive sign-of-life errors of the isochronous controller.
The sign-of-life signal is normally received in PZD4 (control word 2) from the controller.
Dependency:
See also: F01912
Note
The sign-of-life monitoring is disabled for p0925 = 65535.
r0930
PROFIdrive operating mode
 
Data type: Unsigned16
Read permission:
Write permission:
Parameter group:
Unit: -
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Quick commissioning, Configuration
Standard telegram 7, PZD-2/2
Standard telegram 9, PZD-10/5
SIEMENS telegram 111, PZD-12/12
SIEMENS telegram 112, PZD-17/12
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Configuration
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Configuration
Max:
65535
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Configuration
A.3 Parameters
 
 
 
Factory setting:
1
 
Appendix
725

Advertisement

Table of Contents
loading