A01100
CU: Memory card withdrawn
Message class:
General drive fault (19)
Message value:
-
Component:
Control Unit (CU)
Response:
NONE
Acknowledgment: NONE
Cause:
The memory card (non-volatile memory) was withdrawn during operation.
Notice:
It is not permissible for the memory card to be withdrawn or inserted under voltage.
Remedy:
- Switch off the drive system.
- Re-insert the memory card that was withdrawn - This card must match the drive system.
- Switch on the drive system again.
F01105
CU: Insufficient memory
Error in the parameterization / configuration / commissioning procedure (18)
Message class:
Message value:
%1
Component:
Control Unit (CU)
Response:
OFF1
Acknowledgment: POWER ON
Cause:
The functionality on this Control Unit is too extensive (e.g. too many drives, functions, data sets, Technology Extensions,
blocks, etc).
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy:
- Change the configuration on this Control Unit, e.g.
-- Use fewer axes
-- Reduce the number of configurable functions
-- Use fewer data sets
-- Reduce Technology Extensions and blocks
- Use an additional Control Unit.
F01107
CU: Save to memory card unsuccessful
Message class:
Hardware/software error (1)
Message value:
%1
Component:
Control Unit (CU)
Response:
NONE
Acknowledgment: IMMEDIATELY
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
System messages
12.3 Faults and alarms
451

Advertisement

Table of Contents
loading

Table of Contents