Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 753

Servo drive system
Table of Contents

Advertisement

p1663[0]
Current setpoint filter 2 denominator natural frequency
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: Hz
 
Min:
0.5 [Hz]
Description:
Sets the denominator natural frequency for current setpoint filter 2 (PT2, general filter).
Dependency:
Current setpoint filter 2 is activated via p1656.1 and parameterized via p1662 ... p1666.
p1664[0]
Current setpoint filter 2 denominator damping
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0.001
Description:
Sets the denominator damping for current setpoint filter 2.
Dependency:
Current setpoint filter 2 is activated via p1656.1 and parameterized via p1662 ... p1666.
p1665[0]
Current setpoint filter 2 numerator natural frequency
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: Hz
 
Min:
0.5 [Hz]
Description:
Sets the numerator natural frequency for current setpoint filter 2 (general filter).
Dependency:
Current setpoint filter 2 is activated via p1656.1 and parameterized via p1662 ... p1666.
p1666[0]
Current setpoint filter 2 numerator damping
 
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0.000
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Current setpoint filter
Max:
16000.0 [Hz]
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Current setpoint filter
Max:
10.000
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Current setpoint filter
Max:
16000.0 [Hz]
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Operation
Current setpoint filter
Max:
10.000
A.3 Parameters
 
Factory setting:
1999.0 [Hz]
 
Factory setting:
0.700
 
Factory setting:
1999.0 [Hz]
 
Factory setting:
0.700
Appendix
751