Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 839

Servo drive system
Table of Contents

Advertisement

r3988
Final boot state
 
Data type: Integer16
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Displays the final boot states.
001 - Software error
200 - Carry out first commissioning
250 - Topology error (check the connected hardware)
800 - Ready
The following options are available to reach the "Ready" state:
- Check the project and load again.
- Restore factory setting.
- Check the hardware.
- Carry out a POWER ON (switch-off/switch-on).
p4405
PTO maximum output frequency
S200 PN
Data type: FloatingPoint32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: kHz
 
Min:
1 [kHz]
Description:
Sets the maximum output frequency for encoder emulation.
NOTICE
The hardware is designed for a maximum PTO output frequency of 4 MHz. To tolerate any overshoot as a result of the
motor control, p4405 can be set approximately 10 % above 4 MHz.
p4408
PTO pulse number
S200 PN
Data type: Unsigned32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Sets the pulse number output from the PTO.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
System identification
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Commissioning
Pulse encoder emulation
Max:
5000 [kHz]
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Commissioning
Pulse encoder emulation
Max:
16777216
A.3 Parameters
 
 
Factory setting:
1000 [kHz]
 
Factory setting:
1024