Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 705

Servo drive system
Table of Contents

Advertisement

r0068
Absolute current actual value
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: Arms
Description:
Displays actual absolute current.
Dependency:
See also: r0027
NOTICE
For A_INF, S_INF the following applies:
The value is updated with the current controller sampling time.
The following applies for SERVO:
The value is updated with a sampling time of 1 ms.
Note
Absolute current value = sqrt(Iq^2 + Id^2)
The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
r0070
Actual DC link voltage
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: V
Description:
Display and numerical signal source for the measured actual value of the DC link voltage.
Dependency:
See also: r0026
Note
The DC link voltage is available smoothed (r0026) and unsmoothed (r0070).
r0072
Output voltage
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: Vrms
Description:
Display for the actual output voltage of the power unit.
r0076
Current actual value field-generating
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: Arms
Description:
Display for the field-generating current actual value.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Mode signals / displays
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Vdc-min/max controller, Mode signals / displays, Power unit, Vdc controller
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
U/f control, Current controller, Mode signals / displays, Power unit
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
U/f control, Current controller, Mode signals / displays
A.3 Parameters
 
 
 
 
Appendix
703

Advertisement

Table of Contents
loading

Table of Contents