p4422.0
PTO configuration
S200 PN
Data type: Unsigned16
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
-
Description:
Settings for Pulse Train Output (PTO).
Bit array:
Bit
 
00
Dependency:
See also: c4420
p4426
PTO zero mark offset
S200 PN
Data type: Unsigned32
Read permission:
Write permission:
Can be changed in the operating
state:
Parameter group:
 
Unit: -
 
Min:
0
Description:
Sets a zero mark offset to shift the zero mark within one mechanical revolution.
Example:
p0408 = 2048 (encoder pulses)
p4426 = 512 (zero mark offset in pulses)
--> Positive direction: The zero mark is output offset by 512 pulses.
--> Negative direction: The zero mark is output offset by 1536 pulses.
Dependency:
See also: p0408
Note
The setting for the zero mark offset (p4426) must be less than the encoder pulse number (p4408).
r4479
PTO diagnostics position actual value
 
Data type: Integer32
Read permission:
Write permission:
Parameter group:
Unit: -
Description:
Display and numerical signal source for the PTO position actual value.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Signal name
PTO position actual value
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Commissioning
Pulse encoder emulation
Max:
-
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Commissioning
Pulse encoder emulation
Max:
16777215
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Pulse encoder emulation
A.3 Parameters
 
Factory setting:
0000 bin
1 signal
0 signal
Inverted
Not inverted
 
Factory setting:
0
 
Appendix
 
 
839