Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 443

Servo drive system
Table of Contents

Advertisement

Cause:
The write access to the removable data medium was unsuccessful.
Remedy:
- Check the removable data medium and if required replace.
- Repeat the data backup.
A01020
Writing to RAM disk unsuccessful
Message class:
Hardware/software error (1)
Message value:
-
Component:
Control Unit (CU)
Response:
NONE
Acknowledgment: NONE
Cause:
A write access to the internal RAM disk was unsuccessful.
Remedy:
Adapt the file size for the system logbook to the internal RAM disk (p9930).
F01023
Software timeout (internal)
Message class:
Hardware/software error (1)
Message value:
%1
Component:
Control Unit (CU)
Response:
NONE
Acknowledgment: IMMEDIATELY
Cause:
An internal software timeout has occurred.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy:
- Carry out a POWER ON (switch-off/switch-on) for all components.
- Upgrade firmware to later version.
- Contact Technical Support.
F01030
Sign-of-life failure for master control
Message class:
Communication error to the higher-level control system (9)
Message value:
-
Component:
None
Response:
OFF3
Acknowledgment: IMMEDIATELY
Cause:
For active PC master control of the PC, no sign-of-life was received within the monitoring time.
The master control was returned to the drive.
Remedy:
Set the monitoring time higher at the PC or, if required, completely disable the monitoring function.
The monitoring time is set as follows using the commissioning tool:
<Drive> -> Commissioning -> Control panel -> Button "Fetch master control" -> A window is displayed to set the monitoring
time in milliseconds.
Notice:
The monitoring time should be set as short as possible. A long monitoring time means a late response when the
communication fails!
A01032
All parameters must be saved
Message class:
Hardware/software error (1)
Message value:
%1
Component:
Control Unit (CU)
Response:
NONE
Acknowledgment: NONE
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
System messages
12.3 Faults and alarms
441

Advertisement

Table of Contents