System messages
12.3 Faults and alarms
Remedy:
Adapting topologies:
- Connect the expected component (correct the actual topology).
- Adapt the project/parameterizing in the commissioning tool (correct the target topology).
 
Note:
Under "Topology --> Topology view" the commissioning tool where relevant offers improved diagnostics capability (e.g.
setpoint/actual value comparison).
A01425
Topology: Serial number different
Message class:
Error in the parameterization / configuration / commissioning procedure (18)
Message value:
Component: %1, %2, differences: %3
Component:
None
Response:
NONE
Acknowledgment: NONE
Explanation of the
For %1
message value:
 
Component in target topology
Explanation of the
For %2
message value:
 
Value Cause
0
Component unknown
1
Control Unit
2
Motor Module
3
Line Module
4
Sensor Module
5
Voltage Sensing Module
6
Terminal Module
7
DRIVE-CLiQ Hub Module
8
Controller Extension
9
Filter module
10
Hydraulic Module
49
DRIVE-CLiQ component
50
Option slot
60
Encoder
70
DRIVE-CLiQ motor
71
Hydraulic cylinder
72
Hydraulic valve
80
Motor
Cause:
The topology comparison has detected differences in the actual and target topologies in relation to one component. The
serial number is different.
Alarm value (r2124, interpret hexadecimal):
ddccbbaa hex:
dd = reserved
cc = number of differences (%3)
bb = component class (%2)
aa = component number (%1)
Note:
The component class is described in F01375.
The drive system is no longer booted. In this state, the drive control (closed-loop) cannot be enabled.
466
Remedy
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB