• Ramp-down times
After an OFF1 command, and for a quick stop OFF3.
• Forced opening of the brake
Only if the motor being used is equipped with a holding brake.
Requirement
• The drive has been completely created and completely specified in the device configuration.
• For activated user management (UMAC):
The function rights required to read the drive data are activated for your user account.
Details on this topic are provided in Chapter "Security settings in Startdrive" of Industrial
Cybersecurity Configuration Manual
109810578).
Procedure
Proceed as follows to carry out the basic parameterization:
1. Change the default settings of this function view.
2. Optionally, if the motor being used is equipped with a "Standard holding brake", and you wish
to permanently open this brake:
Click "Force open brake".
3. Save the project to apply the settings.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
(https://support.industry.siemens.com/cs/ww/en/view/
Commissioning (Startdrive)
8.7 Configuring the converter
277