Figure 8-9
Defining traversing range limitation
Step 4: Defining traversing range limitation
1. Activate option "SW limit switch activation" if you wish to limit the traversing range using the
software.
2. Then enter the values for the negative end position and the positive end position.
Both values are preassigned with the factory settings.
3. Activate option "HW limit switch activation" if you wish to limit the traversing range
optionally or additionally on the hardware side.
4. Save the settings.
Result
Startdrive defines the default settings of the setup based on what you have specified. These
default settings have an impact on the following EPOS settings in the guided quick startup or
under "Parameterization > Technology functions > Basic positioner".
8.6.6

Application settings

Overview
Make the positioning settings for EPOS in quick startup step "Application settings". The
positioning settings listed depend on the defined application area.
Description of function
You can make the following EPOS settings:
• Active homing
• Absolute encoder adjustment
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Commissioning (Startdrive)
8.6 Carrying out guided quick startup
265