Siemens SINAMICS SIMOTICS S200 PROFINET Operating Instructions Manual page 701

Servo drive system
Table of Contents

Advertisement

Note
For index [0]:
This index shows the actual state of the I2t monitoring on the AC side.
The reference value represents the AC current that the power unit can permanently provide, without the influence of
switching losses (e.g. the continuously permissible current of capacitors, inductances, busbars, etc.).
For index [1]:
This index shows the actual state of the active power monitoring.
The reference value represents the active power that the power unit can continuously provide.
For index [2]:
This index shows the actual state of the I2t monitoring on the DC side.
The reference value represents the DC current that can continuously flow in the DC link.
r0037[0...10]
Power unit temperatures
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: °C
Description:
Display for the temperatures in the power unit.
Index:
[0] = Inverter maximum value
[1] = Depletion layer maximum value
[2] = Rectifier maximum value
[3] = Air intake
[4] = Interior of power unit
[5] = Cooling unit liquid intake
[6] = Capacitor air discharge
[7] = Depletion layer maximum value 1
[8] = Depletion layer maximum value 2
[9] = Depletion layer maximum value 3
[10] = Depletion layer maximum value 4
Note
The value of -200 indicates that there is no measuring signal.
r0037[0]: Maximum value of the inverter temperatures.
r0037[1]: Maximum value of the depletion layer temperatures.
In the case of a fault, the particular shutdown threshold depends on the power unit, and cannot be read out.
r0039[0...2]
Energy display
 
Data type: FloatingPoint32
Read permission:
Write permission:
Parameter group:
Unit: kWh
Description:
Display for the energy values at the drive output terminals.
Index:
[0] = Energy balance (sum)
[1] = Energy drawn
[2] = Energy fed back
Note
For index [0]:
Difference between the energy drawn and energy that is fed back.
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB
Visible in: Extended display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Mode signals / displays, Power unit
Visible in: Standard display
Read drive data or acknowledge messages
Edit device configuration or drive applications
Mode signals / displays, Power loss optimization
A.3 Parameters
 
 