Dicom conformance statement print management service class fuji network print server (54 pages)
Summary of Contents for FujiFilm FN-PS551
Page 1
FUJI MEDICAL LASER IMAGER FUJI NETWORK PRINT SERVER FN-PS551 SERVICE MANUAL Document No. 006-251-07 First Edition: Oct. 30, 1998 Revised: Oct. 28, 2002 Fuji Photo Film Co., Ltd. Printed in Japan...
Page 2
Fuji Photo Film Co., Ltd. Miyanodai Technology Development Center. 006-251-07 FN-PS551 Service Manual 10.28.2002 FM3487...
Page 3
Notice Due to the sensitive nature of the specialized software contained within the computer, ADDITIONAL APPLICATIONS, OPERATING SYSTEM CHANGES/UPGRADES, FOREIGN DRIVERS, OTHER FILES OR INPUT/OUTPUT DEVICES NOT AUTHORIZED BY FUJI IN WRITING SHOULD NOT BE INSTALLED ON THIS SYSTEM. Service calls resulting from the introduction of unapproved software, firmware or hardware are NOT covered under warranty or service contracts and will be billed at prevailing hourly rates.
Page 5
FUJI MEDICAL SYSTEMS U.S.A., INC. APPLICATION PROVIDER LICENSE AGREEMENT END USER LICENSE TERMS Initial use of the software by the purchaser constitutes acceptance of these terms. (1) Only a non-exclusive, nontransferable right to use this Fuji Software on a Fuji- approved computer system is granted to the licensee.
Page 6
FUJI MEDICAL SYSTEMS U.S.A., INC. LICENSE AGREEMENT CONTINUED (8) Fuji shall have the right to direct a recognized accounting firm to conduct, during normal business hours, an audit of (and to copy) the appropriate records of the licensee to verify the number of copies of the Software in Use by the licensee, the computer systems on which such copies are installed and in the case of limited user licenses, the number of users using such copies.
Page 7
BLANK PAGE 006-251-00 FN-PS551 Service Manual 10.30.98 FM2327...
Page 8
High voltage is used inside the CRT monitor. To prevent electric hazards and danger, the CRT monitor internal parts cannot be accessed. (The CRT monitor does not consist of parts servicable by the service engineer.) 006-251-07 FN-PS551 Service Manual 10.28.2002 FM3487...
Page 9
Maintenance of the Control unit Maintenance of Control Unit For repairs and maintenance of the control unit (including the keyboard and mouse) and/or monitor of the Fuji Photo Film-supplied FN-PS551, contact the Dell service center in your country. 006-251-00 FN-PS551 Service Manual...
Page 10
Maintenance-1 Fuji Network Print Server FN-PS551 Service Manual MAINTENANCE Control Sheet Issue Date Revision Reason Pages Affected 10/30/98 New release (FM2327) All pages 05/12/99 Revision All pages (Software ver. A02 / DICOM function expanded, etc.) (FM2442) 08/11/99 Revision 2~7, 9, 25, 32, 33, 41, 42, 47, 50, 51, (Software ver.
System Overview ....................4 Example of System Configuration ............4 Outline of Specifications ..............5 Normal Operation Display ..............6 Basic Configuration of the FN-PS551 ............10 Basic Configuration ................10 Detailed Specifications ..............11 Error Codes ...................... 12 Source Name ..................12 Error Messages, Causes, and Remedies ..........
Page 12
Installing System Utilities..............234 Setting System Startup Latency and Task Bar Display ....240 Installing the FN-PS551 Application and Key Registry ....244 Setting the Language for FN-PS551 Application ......248 Setting the Control Unit (PC) to Use PEI01A Board ........254 Setting GX1/GX110 Series Control Unit ........
Page 13
Formatting the D Drive ..............293 11.4 Setting System Startup Latency and Task Bar Display ....294 11.5 Installing the Printer Interface Board ..........295 11.6 Setting the Language for FN-PS551 Application ......296 006-251-07 FN-PS551 Service Manual Maintenance-3.1 10.28.2002 FM3487...
Maintenance 1. System Overview System Overview The Fuji Network Printer Server FN-PS551 is a printer server system designed to enable a large number of image diagnostic devices (for IM images) such as X-ray CT and MRI systems, and Fuji Photo Film’s FCR systems (for CR images; supporting software ver.
Norwegian (Bokmal), Swedish, Spanish (Modern Sort or Spain), Danish TP4F0001.EPS NOTE • The FUJI specifications based image reception protocol and CR image processing support software ver. A03 or later. • The specifications of the hardware are subject to change without notice. 006-251-07 FN-PS551 Service Manual Maintenance-5 10.28.2002 FM3487...
Maintenance-6 Maintenance 1. System Overview Normal Operation Display The following [FN-PS551] window appears on the monitor display during normal operation of the FN-PS551. NOTE [FN-PS551] windows are shown in English as follows. To change the display to a language other than English, refer to Section 8.9, "Setting the Language for FN-PS551 Application".
Page 20
8in * 10in: 2025 (8in * 10in: 2025 is applicable to software ver. A05 or later.) TP4F0002.EPS Display of Title Bar [11] Shows the version of FN-PS551 application software Shows active function(s) (a maximum of three functions) of [12] [DICOM] [TOSHIBA] FN-PS551 application.
Page 21
When using software ver. A03 or earlier: • The print from a client is not accepted with either of the DICOM/TOSHIBA/FUJI protocols until the status of the printer becomes [Operating] when the FN-PS551 application is started. • The print acceptance varies depending on the protocol when the status of the printer is changed from [Operating] to other status while operating the FN-PS551 application after it is started up.
Page 22
Maintenance-9 Maintenance 1. System Overview BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-9 03.30.2000 FM2730...
Maintenance-10 Maintenance 2. Basic Configuration of the FN-PS551 Basic Configuration of the FN-PS551 To Network Control main unit Monitor Printer IF board Application To printer software Key registry software Keyboard and mouse FP4F0003.EPS Basic Configuration Component Description Control unit Windows NT or XP PC...
Maintenance-11 Maintenance 2. Basic Configuration of the FN-PS551 Detailed Specifications Control Unit Item Details Pentium II, Pentium III, or Pentium IV 400 MHz or higher System memory 128 MB or more 3.2 GB or more CD-ROM drive Built-in 3.5" FD drive...
The Event Viewer records a wide range of events generated by Windows NT/XP in addition to errors occurred at the FN-PS551 application. The FN-PS551 application uses the following source names. After clicking [View] and then [Search] in the [Event Viewer], specifying one of the source names extracts and displays only necessary events.
%n%1 method call failed. the system is installed correctly. Error Calling 'AnsPrinterInfo' The printer information Restart, and/or check that method failed. %n%1 request answer method the system is installed call failed. correctly. TP4F0009.EPS 006-251-03 FN-PS551 Service Manual Maintenance-13 03.30.2000 FM2730...
Page 27
Restart, and/or check that method failed. %n%1 request calling failed. the system is installed correctly. Error File copy error. %n%1 File copying error. Restart, and/or check that the system is installed correctly. TP4F0010.EPS 006-251-03 FN-PS551 Service Manual Maintenance-14 03.30.2000 FM2730...
Page 28
(Illegal input data)Image set The message set ID in Check the status of the ID is invalid. the received image is other device, the operation incorrect. at the time of transmission, and the transmitted images. TP4F0011.EPS 006-251-03 FN-PS551 Service Manual Maintenance-15 03.30.2000 FM2730...
Page 29
FN-PS and network settings in Network menu of Control Panels. (If the problem seems to be with the other device at the connection end, check the settings at the other device.) TP4F0012.EPS 006-251-03 FN-PS551 Service Manual Maintenance-16 03.30.2000 FM2730...
Page 30
Warning (Internal process error)Error A fork error occurred in a Restart. occurred with creating sub-process. thread. Warning (Network error)Error A socket control error Restart. occurred in socket control. occurred. TP4F0013.EPS 006-251-03 FN-PS551 Service Manual Maintenance-17 03.30.2000 FM2730...
Page 31
The overlay size Check the status of the of overlay is out of limitation. (columns) of the other device, the operation received image is at the time of transmission, incorrect. and the transmitted images. TP4F0014.EPS 006-251-03 FN-PS551 Service Manual Maintenance-18 03.30.2000 FM2730...
Page 32
Check the other device and occurred in sending data. during data network cabling. transmission. A timeout occurred Warning (Network error)Timeout Check the other device and occurred in receiving data. during data reception. network cabling. TP4F0015.EPS 006-251-03 FN-PS551 Service Manual Maintenance-19 03.30.2000 FM2730...
Page 33
(wait port number the Service Utility. disabled). Error Initialization Memory was insufficient Restart, and/or check that failed.[Insufficient memory] during the DICOM the system is installed initialization procedure. correctly. TP4F0017.EPS 006-251-03 FN-PS551 Service Manual Maintenance-20 03.30.2000 FM2730...
Page 34
Error Image processing error. All attempts at image Check that the print job %n%1 processing result in and the film objects and error. the image processing parameters are set correctly. TP4F0019.EPS 006-251-03 FN-PS551 Service Manual Maintenance-21 03.30.2000 FM2730...
Page 35
Warning Change priority is invalid. The designated Check the method %n%1 priority change is not parameters for the priority valid. change. TP4F0020.EPS 006-251-03 FN-PS551 Service Manual Maintenance-22 03.30.2000 FM2730...
Page 36
The Service Utility If the Service Utility may Utility. started up. (This have been started up by event is recorded non-service personnel, when the Service check all settings. Utility is started up.) TP4F0021.EPS 006-251-03 FN-PS551 Service Manual Maintenance-23 03.30.2000 FM2730...
(creation, open or deletion of files). Application Log: The application log contains specific events logged by the FN-PS551 application. The application developer determines which events to be monitored. 006-251-07 FN-PS551 Service Manual Maintenance-24...
Page 38
Maintenance-25 Maintenance 4. Event Viewer Errors occurring in the FN-PS551 application are recorded in the application log. The following procedure describes how to display the application log. • For Windows NT Click the [Log] menu on the [Event Viewer] window, then click [Applications].
From the [Control panel] window, click the [Performance and Maintenance]. From the [Performance and Maintenance] window, click the [Administrative Tools]. From the [Administrative Tools] window, double-click the [Event Viewer]. → The Event Viewer starts, and the [Event Viewer] window appears. 006-251-07 FN-PS551 Service Manual Maintenance-25.1 10.28.2002 FM3487...
: The name of the user logged in before the event occurred. Where the relevant software dose not identify user names, the [User] column reads “N/A”. [Computer] : The name of the computer in use when the event occurred. 006-251-07 FN-PS551 Service Manual Maintenance-25.2 10.28.2002 FM3487...
Layout and View of Event Viewer Window” in the section “4.1 Using the Event Viewer”. Note that [Type] corresponds to the meaning of an icon and [Event ID] to the identifier number of an event. 006-251-07 FN-PS551 Service Manual Maintenance-25.3 10.28.2002 FM3487...
Insert the floppy disk for saving event logs into the disk drive. From the [Log] menu, click [Save As...]. → The [Save As...] dialog appears. In the [Save in:] box, choose “3 1/2 Floppy (A:)”. 006-251-07 FN-PS551 Service Manual Maintenance-25.4 10.28.2002 FM3487...
Page 43
→ The [Save “Application” As] dialog disappears once the save operation has been successfully completed. Remove the floppy disk after checking that the access lamp on the floppy disk drive has gone out. 006-251-07 FN-PS551 Service Manual Maintenance-26 10.28.2002 FM3487...
→ The message [Do you want to save “Application log” before clearing it ?] appears prompting to enter a Yes or No. Click [No] to proceed without saving event logs. → All log entries on the [Event Viewer] window are cleared. 006-251-07 FN-PS551 Service Manual Maintenance-27 10.28.2002 FM3487...
For Windows NT, from the [Log] menu, click [Exit] to exit from the event viewer. For Windows XP, from the [File] menu, click [Exit] to exit from the event viewer. → The [Event Viewer] window closes, and the event viewer is terminated. 006-251-07 FN-PS551 Service Manual Maintenance-28 10.28.2002 FM3487...
For futher advice and/or repairs, contact the DELL service center in your country. • All maintenance parts for the FN-PS551 made available through Fuji Photo Film are listed in the following section “6. Service Parts List”.
(s) are used to identify Parts applicable to Export regulations. the function of the part. For parts having different functions, they are clearly TP4F0024.EPS distinguished in the REMARKS and SERIAL NUMBER columns. 006-251-03 FN-PS551 Service Manual Maintenance-32 03.30.2000 FM2730...
Page 50
The use of different packing materials or packing methods may incur damage to packed parts during transit. 006-251-03 FN-PS551 Service Manual Maintenance-33 03.30.2000 FM2730...
Maintenance-34 Maintenance 6. Service Parts List Parts List NOTE The diagram shown below is an example of parts appearance. Appearance varies depending on the control unit model used. FP4F0011.EPS 006-251-07 FN-PS551 Service Manual Maintenance-34 10.28.2002 FM3487...
Page 52
(128MB for GX110/GX150) TP4F0026.EPS NOTE The FN-PS551 application software products (CD-ROM) and DICOM or TOSHIBA or IPU or PEM key registry software products (floppy disk) must be ordered. Refer to the Product Components list in “2.3 Checking Contents” of the “Service Manual-Installation”.
Page 53
Maintenance-36 Maintenance 6. Service Parts List BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-36 03.30.2000 FM2730...
Page 54
Maintenance-37 Maintenance 6. Service Parts List BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-37 03.30.2000 FM2730...
Page 55
Maintenance-38 Maintenance 6. Service Parts List BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-38 03.30.2000 FM2730...
Page 56
Maintenance-39 Maintenance 6. Service Parts List BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-39 03.30.2000 FM2730...
The service utility checks, sets and changes each parameter as required. Starting Up and Exiting the Service Utility Starting Up the Service Utility If the FN-PS551 application is running, click [Exit] on the [Exit] menu in the [FN-PS551] window or clicking the close box in the top right-hand corner of the window to close it.
Page 58
Maintenance-41 Maintenance 7. Service Utility → The [SERVICE UTILITY] window appears (the [Protocols] window opens at the initial state). (Software ver. A00) (Software ver. A02 or later) 006-251-03 FN-PS551 Service Manual Maintenance-41 03.30.2000 FM2730...
• Click the [Cancel] button to exit from the service utility without saving changes. All previous settings remain. REFERENCE Clicking the close box at the top right-hand corner of the window produces the same result as clicking [Cancel]. 006-251-03 FN-PS551 Service Manual Maintenance-42 03.30.2000 FM2730...
Page 60
Maintenance-43 Maintenance 7. Service Utility BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-43 03.30.2000 FM2730...
Set parameters for the TOSHIBA protocol. [2] → Printer Lists all registered printers. name Specify the printer name. interface Set printer interface information. model Specify production model information. sorting Specify sort conditions (when applicable). FP4F0015.EPS 006-251-05 FN-PS551 Service Manual Maintenance-44 05.30.2001 FM3069...
Page 62
Maintenance-45 Maintenance 7. Service Utility [3] → Clients Lists all clients (image diagnostic systems) connected to the FN-PS551 via network. name Specify client ID information. protocol Specify the protocol for connection to the client. DICOM To set a new DICOM protocol client.
(Available with software ver. A03 or later although it appears even with software ver.A02 or later) [2] → Printer Lists all registered printers. name Specify the printer name. interface Set printer interface information. model Specify production model information. FP4F0301.EPS 006-251-05 FN-PS551 Service Manual Maintenance-46 05.30.2001 FM3069...
Page 64
(Available with software ver. A03 or later although it appears IPU 35 to 39 even with software ver. A02 or later) [6] → Logging Specify log data acquisition and other settings. [7] → Sorting Specify sort conditions (When applicable). FP4F0303.EPS 006-251-05 FN-PS551 Service Manual Maintenance-47 05.30.2001 FM3069...
DICOM protocol: add protocol or modify parameters FUJI protocol: add protocol or modify parameters (Available with software ver. A03 or later although it appears even with software ver. A02 or later) 006-251-07 FN-PS551 Service Manual Maintenance-48 10.28.2002 FM3487...
Page 66
Only protocols enabled by the key registry software are available for use. Selecting another protocol dose not make it available for use. • FN-PS551 supports the following three protocols (when the appropriate key registry software programs must be installed): • DICOM: Specify DICOM parameters.
Maintenance-50 Maintenance 7. Service Utility Display of [Protocols] Window From the [SERVICE UTILITY] window, click the [Protocols] tab. → The [Protocols] window appears. (Software ver. A00) (Software ver. A02 or later) 006-251-03 FN-PS551 Service Manual Maintenance-50 03.30.2000 FM2730...
Page 68
(go to “ Using Parameter Settings Windows”). To Delete a Registered Protocol From the [Protocols:] list in the [Protocols] window, select a protocol to delete, then click [Remove]. → The selected protocol is deleted. 006-251-03 FN-PS551 Service Manual Maintenance-51 03.30.2000 FM2730...
[DICOM Property] Window The [DICOM Property] window appears to add a protocol or view/modify protocol settings when the “DICOM” is selected from the [Protocols:] list. (Software ver. A03 or earlier) (Software ver. A04 to A06) 006-251-07 FN-PS551 Service Manual Maintenance-52 10.28.2002 FM3487...
Page 70
The transmission timeout value can be specified in the range of 30 to 3,600 seconds (the default value is 600 seconds). The timeout value represents the maximum time limit for the FN-PS551 to wait for data to arrive. If data does not arrive within the set time, a timeout occurs.
Page 71
30sec., a reject (connection disabled) message is returned to the client requesting connection. • In the case of a client connecting with FN-PS551, max. memory capacity used by the client is stored. Based on this data, the expected memory capacity that may be used by a client requesting a connection is judged.
Page 72
This parameter specifies the type of application entity titles (AE Title) assigned to the FN-PS551 system. When two printers are connected, an AE Title for each printer (so that the each printer are seen as an independent unit) or an AE Title for the complete system (so that two printers are seen as a single unit) can be specified.
Page 73
Maintenance-53.3 Maintenance 7. Service Utility BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-53.3 10.28.2002 FM3487...
Page 74
Maintenance-53.4 Maintenance 7. Service Utility BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-53.4 10.28.2002 FM3487...
Page 75
Maintenance-54 Maintenance 7. Service Utility [TOSHIBA Property] Window The [TOSHIBA Property] window appears to add a protocol or view/modify protocol settings when the “TOSHIBA” is selected from the [Protocols:] list. 006-251-03 FN-PS551 Service Manual Maintenance-54 03.30.2000 FM2730...
Page 76
• [thrown away]: Received data is discarded. • [printed]: Received data alone is printed. Set the parameters and click [OK]. → The [Protocols] window on the [SERVICE UTILITY] window reappears. 006-251-03 FN-PS551 Service Manual Maintenance-55 03.30.2000 FM2730...
Page 77
[FINP Property] Window (supporting software ver. A03 or later) The [FINP Property] window appears to add a protocol or view/modify protocol settings when the “Multi Modality DMS (FINP)” is selected from the [Protocols:] list. (Software ver. A03) 006-251-03 FN-PS551 Service Manual Maintenance-56 03.30.2000 FM2730...
Page 78
• To use the IPU function, specify parameters according to the procedure described in the “ Setting Image Processing”, “ Setting Parameter Updating Editor” and “ Setting Data recieve if the printer is off-line”. 006-251-03 FN-PS551 Service Manual Maintenance-57 03.30.2000 FM2730...
Page 79
Even if [Parameter Updating Editor] is usable, editable parameters vary depending on various setting details. • Refer to the “FN-PS551 Operation Manual” for further information about the Parameter Updating Editor including how to use it. 006-251-05 FN-PS551 Service Manual Maintenance-58 05.30.2001 FM3069...
Page 80
[Operating]. • [disable]: Print is only accepted in the [Operating] status while starting up or operating the FN-PS551 application. Set the parameters and click [OK]. → The [Protocols] window on the [SERVICE UTILITY] window reappears.
Page 81
Maintenance-60 Maintenance 7. Service Utility BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-60 03.30.2000 FM2730...
Page 82
Maintenance-61 Maintenance 7. Service Utility BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-61 03.30.2000 FM2730...
: Select a printer to delete, and then click [Remove]. When adding a printer or modifying parameters, go through all “Printer Property” tabs. Add... Properties... Name Remove Interface Model Sorting (Using software ver. A00) 006-251-05 FN-PS551 Service Manual Maintenance-62 05.30.2001 FM3069...
Maintenance-63 Maintenance 7. Service Utility Display of [Printer] Window From the [SERVICE UTILITY] window, click the [Printer] tab. → The [Printer] window appears. (software ver. A00) (software ver. A02 or later) 006-251-03 FN-PS551 Service Manual Maintenance-63 03.30.2000 FM2730...
Page 85
→ The [Printer Property] window appears (go to “ Using [Printer Property] Window”). To Delete a Registered Printer From the [Printers:] list of the [Printers] window, select a printer to delete, then click [Remove]. → The selected printer is deleted. 006-251-03 FN-PS551 Service Manual Maintenance-64 03.30.2000 FM2730...
Page 86
Maintenance-65 Maintenance 7. Service Utility BLANK PAGE 006-251-03 FN-PS551 Service Manual Maintenance-65 03.30.2000 FM2730...
(“Printer #1” is connected to the first printer interface board). • There are four setting windows (three for software ver. A02 or later). Use the tabs to move among windows. [Name] Window (Software ver. A00) (Software ver. A02 to A04) 006-251-05 FN-PS551 Service Manual Maintenance-66 05.30.2001 FM3069...
Page 88
Maintenance-67 Maintenance 7. Service Utility (Software ver. A05 or later) (When [fine printing] is specified with software ver. A05 or later) 006-251-05 FN-PS551 Service Manual Maintenance-67 05.30.2001 FM3069...
Page 89
NOTE • The printer name entered in a field [Name (AE Title of DICOM):] is displayed as the [Equipment] in the [Equip. Status] list of the [FN-PS551] window. It is also used for “ [Printer] Window” in the “7.5 Adding, Modifying, or Deleting a Client [Client]”.
Page 90
Maintenance-69 Maintenance 7. Service Utility Click the [Interface] tab. → The [Interface] window appears. 006-251-07 FN-PS551 Service Manual Maintenance-69 10.28.2002 FM3487...
Page 91
Maintenance-70 Maintenance 7. Service Utility [Interface] Window (Software ver. A00) (Software ver. A02 or later) 006-251-04 FN-PS551 Service Manual Maintenance-70 07.24.2000 FM2824...
Page 92
60 m, choose [2.0 µ sec/pixel]. NOTE Set the transfer speed to the printers indicated below to [2.0 µ sec/pixel]. FL-IM2636N, FL-IM3543N, FL-IM3543MN Setting to [1.0 µ sec/pixel] will cause a transfer error between the FN-PS551 and these printers. • [version:]: Specifies the interface version.
Page 93
Maintenance-72 Maintenance 7. Service Utility [Model] Window (Software ver. A00) (Software ver. A02 or later) 006-251-04 FN-PS551 Service Manual Maintenance-72 07.24.2000 FM2824...
Page 94
• Normally the default for the model and manufacturer names should be used (“FN-PS551” and “FUJI PHOTO FILM CO., LTD” respectively). Where multiple FN-PS551 systems are installed at a single location, each must be identified by a unique name determined in consultation with the users.
Page 95
For software ver. A02 or later, the [Sorting] window is moved from the [Printer Property] window to the [SERVICE UTILITY] window. Refer to the section “7.9 Setting Sorting Conditions [Sorting]” for using software ver. A02 or later. 006-251-04 FN-PS551 Service Manual Maintenance-74 07.24.2000 FM2824...
Page 96
Modality Code, they are not differentiated. • [by unique ID] : This parameter is disabled (not currently available). When all settings have been successfully completed, click [OK]. → The [Printer] window on the [SERVICE UTILITY] window reappears. 006-251-04 FN-PS551 Service Manual Maintenance-75 07.24.2000 FM2824...
: Select a client to delete, and then click [Remove]. When adding a client or modifying client parameters, go through all "Network Client Property" tabs. Add... Properties... name Remove protocol magnify (continued next page) 006-251-06 FN-PS551 Service Manual Maintenance-76 12.18.2001 FM3271...
Page 98
Choose "modality" from "parameter priority:", then Setup... printer output format1 (output format for software ver. A04 or earlier) output format2 Refer to "7.6 Adding, Modifying, (software ver. A05 or Deleting Modality Information". or later) 006-251-07 FN-PS551 Service Manual Maintenance-77 10.28.2002 FM3487...
Maintenance-78 Maintenance 7. Service Utility Display of [Clients] Window From the [SERVICE UTILITY] window, click the [Clients] tab. → The [Clients] window appears. (Software ver. A00) (Software ver. A02 or later) 006-251-04 FN-PS551 Service Manual Maintenance-78 07.24.2000 FM2824...
• For clients connected through FUJI protocol, specify client parameters only on the [name], [protocol] and [printer] windows (for FUJI protocol, client parameters can be specified when software ver. A03 or later is used). 006-251-05 FN-PS551 Service Manual Maintenance-79 05.30.2001 FM3069...
Page 101
• If the “DICOM: default” is selected, the [Host name:] on the [name] window reads “default,” and the host name and IP address settings cannot be changed. Click the [protocol] tab. → The [protocol] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-80 05.30.2001 FM3069...
Page 102
Maintenance-81 Maintenance 7. Service Utility [protocol] Window (adding a client) (Software ver. A00) (Software ver. A02 to A04) 006-251-05 FN-PS551 Service Manual Maintenance-81 05.30.2001 FM3069...
Page 103
Maintenance-82 Maintenance 7. Service Utility (Software ver. A05 or later) [protocol] Window (for “DICOM: default”) (Software ver. A00) 006-251-06 FN-PS551 Service Manual Maintenance-82 12.18.2001 FM3271...
Page 104
Maintenance-83 Maintenance 7. Service Utility (Software ver. A02 to A04) (Software ver. A05 or later) 006-251-06 FN-PS551 Service Manual Maintenance-83 12.18.2001 FM3271...
Page 105
([not indicate] (default) sends no notification, [indicate] sends an error message). • [N-Event-Report RQ:]: This parameter specifies whether to respond to N-Event-Report requests ([disabled] (default) send no response, [enabled] sends a response). 006-251-06 FN-PS551 Service Manual Maintenance-84 12.18.2001 FM3271...
Page 106
• [Use Presentation LUT:] (supporting software ver. A05 or later): For Presentation LUT information sent by client, choose either [No] (use LUT content set for FN-PS551) or [Yes] (use LUT content sent by client, default). If print is not output with expected tone using LUT information sent by client, adjust to output print with proper tone using LUT setting of FN-PS551.
Page 107
Maintenance-86 Maintenance 7. Service Utility For the TOSHIBA protocol connection, set the following parameters. (Software ver. A00) (Software ver. A02 or later) 006-251-04 FN-PS551 Service Manual Maintenance-86 07.24.2000 FM2824...
Page 108
Thus, {(1024 × 1024 × 2) + (1024 × 1024 / 8)} × 20 / 1024 + 16 = 43,536 KB • [Multi Modality DMS:]: This parameter is disabled (not currently available). The value “disable” is only valid. The other values are not selectable. 006-251-04 FN-PS551 Service Manual Maintenance-87 07.24.2000 FM2824...
Page 109
(supporting software ver. A03 or later). (Software ver. A02 or later) NOTE The [FINP] in the [protocol] window is available with software ver. A03 or later although it appears even with software ver. A02 or later. 006-251-04 FN-PS551 Service Manual Maintenance-88 07.24.2000 FM2824...
Page 111
Maintenance 7. Service Utility [magnify] Window In the [procedure:], choose [A-VR] or [SSM] for the enlargement/reduction processing method. NOTE • For [A-VR], go to step (9). • For [SSM], go to step (10). 006-251-04 FN-PS551 Service Manual Maintenance-90 07.24.2000 FM2824...
Page 112
(10) For the SSM method, specify a mode in the [default smoothing type:]. • Choose [SHARP], [MEDIUM] or [SMOOTH] mode for the [default smoothing type:]. (11) Click the [LUT] tab. → The [LUT] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-91 07.24.2000 FM2824...
Page 113
[LUT] Window (DICOM protocol for software ver. A03 or earlier) When [SAR] is selected When [BAR] is selected [LUT] Window (TOSHIBA protocol for software ver. A03 or earlier) When [SAR] is selected When [BAR] is selected 006-251-04 FN-PS551 Service Manual Maintenance-92 07.24.2000 FM2824...
Page 114
[LUT] Window (DICOM protocol for software ver. A04 to A06) When [SAR] is selected When [BAR] is selected [LUT] Window (TOSHIBA protocol for software ver. A04 to A06) When [SAR] is selected When [BAR] is selected 006-251-07 FN-PS551 Service Manual Maintenance-93 10.28.2002 FM3487...
Page 115
[LUT] Window (DICOM protocol for software ver. A07 or later) When [SAR] is selected When [BAR] is selected [LUT] Window (TOSHIBA protocol for software ver. A07 or later) When [SAR] is selected When [BAR] is selected 006-251-07 FN-PS551 Service Manual Maintenance-93.1 10.28.2002 FM3487...
Page 116
Maintenance-93.2 Maintenance 7. Service Utility BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-93.2 10.28.2002 FM3487...
Page 117
Maintenance-93.3 Maintenance 7. Service Utility BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-93.3 10.28.2002 FM3487...
Page 118
Maintenance-93.4 Maintenance 7. Service Utility BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-93.4 10.28.2002 FM3487...
Page 119
Appendix” for details (gamma table, etc.) on each of the parameters used by the following LUT settings. • On the FN-PS551 application, it is set not to perform tone correction processing when setting gamma table No. 49 for SAR (used when connecting to QA-WS771 with the DICOM protocol).
Page 120
Follow the rule of minimum density<density ± shift <maximum density. • [contrast:]: Specify the contrast at the tuning point in multiples of 100 (range = 10 to 400). (13) Click the [printer] tab. → The [printer] window appears. 006-251-07 FN-PS551 Service Manual Maintenance-95 10.28.2002 FM3487...
Page 121
Maintenance-96 Maintenance 7. Service Utility [printer] Window (Software ver. A06 or earlier) When [fixed] is selected When [primary/secondary] is selected When [random] is selected 006-251-07 FN-PS551 Service Manual Maintenance-96 10.28.2002 FM3487...
Page 122
Maintenance-97 Maintenance 7. Service Utility [printer] Window (Software ver. A07 or later) When [fixed] is selected When [primary/secondary] is selected When [random] is selected 006-251-07 FN-PS551 Service Manual Maintenance-97 10.28.2002 FM3487...
Page 123
If [one to both printers] (an AE Title is assigned for the system) is set, or for a TOSHIBA protocol client or a FUJI protocol client, the print output is performed to the printer set here. (15) Click the [output format] tab. → The [output format] window appears. 006-251-07 FN-PS551 Service Manual Maintenance-97.1 10.28.2002 FM3487...
Page 124
Maintenance-97.2 Maintenance 7. Service Utility BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-97.2 10.28.2002 FM3487...
Page 125
Maintenance-97.3 Maintenance 7. Service Utility BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-97.3 10.28.2002 FM3487...
Page 126
Maintenance-97.4 Maintenance 7. Service Utility BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-97.4 10.28.2002 FM3487...
Page 127
Maintenance-98 Maintenance 7. Service Utility [output format] Window (Software ver. A00) (Software ver. A02 to A04) 006-251-05 FN-PS551 Service Manual Maintenance-98 05.30.2001 FM3069...
Page 128
Maintenance-99 Maintenance 7. Service Utility ([output format1] for software ver. A05 or later) ([output format2] for software ver. A05 or later) 006-251-05 FN-PS551 Service Manual Maintenance-99 05.30.2001 FM3069...
Page 129
Choose either [blue] or [clear] for the default film base. • [film orientation:]: Choose either [PORTRAIT] or [LANDSCAPE] for the film orientation. • [mirror:]: Choose either [ON (mirror)] (glossy side to front) or [OFF (Normal)] (glossy side to back). 006-251-05 FN-PS551 Service Manual Maintenance-100 05.30.2001 FM3069...
Page 130
• For DICOM protocol, when output image size on a film (width of image) is specified (Requested Image Size) in the image data sent from a client. (17) After completing all settings, click [OK]. → The [Clients] window on the [SERVICE UTILITY] window reappears. 006-251-05 FN-PS551 Service Manual Maintenance-101 05.30.2001 FM3069...
The [Modality Setup] window can be used to add or change parameters by modality and delete registered modality information for the tone correction processing. [Modality Setup] Menu Sequence Choose [modality] in [parameter priority:] Setup... Add... Properties... Remove 006-251-04 FN-PS551 Service Manual Maintenance-102 07.24.2000 FM2824...
For the TOSHIBA protocol, from the [LUT] window, choose [modality] on the [parameter priority:], then click [Setup...]. → The [Modality Setup] window appears. NOTE [Modalities:] lists modalities for which modality-dependent tone correction processing parameters have been set. No modality is registered at installation. 006-251-04 FN-PS551 Service Manual Maintenance-103 07.24.2000 FM2824...
Page 133
→ The [Modality Property] window appears (go to “ Using [Modality Property] Window”). To Delete Registered Modality Information From the [Modalities:] list in the [Modality Setup] window, select a modality to delete, then click [Remove]. → The selected modality is deleted. 006-251-04 FN-PS551 Service Manual Maintenance-104 07.24.2000 FM2824...
Page 134
Maintenance-105 Maintenance 7. Service Utility BLANK PAGE 006-251-04 FN-PS551 Service Manual Maintenance-105 07.24.2000 FM2824...
Maintenance-106 Maintenance 7. Service Utility Using [Modality Property] Window [Modality Property] Window (Software Ver. A03 or earlier) When [SAR] is selected When [BAR] is selected 006-251-04 FN-PS551 Service Manual Maintenance-106 07.24.2000 FM2824...
Page 136
When [BAR] is selected NOTE Refer to “Chapter 2 Service Utility - Additional Instructions 1. Supplementary Explanation for Setting LUT Content” in the “FN-PS551 Service Manual- Appendix” for details (gamma table, etc.) on each of the parameters used by the following LUT settings.
Page 137
To add more modality information, repeat the procedure described in the previous section “ To Add Modality Information”. After adding, viewing, or modifying modality information, click [OK] on the [Modality Setup] window. → The [LUT] window on the [Network Client Property] reappears. 006-251-04 FN-PS551 Service Manual Maintenance-108 07.24.2000 FM2824...
Page 138
Maintenance-109 Maintenance 7. Service Utility BLANK PAGE 006-251-04 FN-PS551 Service Manual Maintenance-109 07.24.2000 FM2824...
For software ver. A02 or later, the [Print Server] tab is shown on the [Annotation] window. NOTE For software ver. A02 or later, click the [Print Server] tab if the [Print Server] is not shown. → The [Annotation] window appears. (Software ver. A00) 006-251-05 FN-PS551 Service Manual Maintenance-110 05.30.2001 FM3069...
Page 140
Maintenance-111 Maintenance 7. Service Utility (Software ver. A02/A03) (Software ver. A04) 006-251-05 FN-PS551 Service Manual Maintenance-111 05.30.2001 FM3069...
Page 141
For this reason, larger fonts may cause characters to be cut off, while overly long messages will not be displayed in full. Check the film output to confirm that the specified annotation text is fully displayed as intended. 006-251-05 FN-PS551 Service Manual Maintenance-112 05.30.2001 FM3069...
Page 142
Specify a font type and size in the [Font] and [Size] on the [Font] window, and then click [OK]. NOTE The [Font style] to output an annotation text is fixed at “Regular”. → The [Annotation] window reappears. 006-251-05 FN-PS551 Service Manual Maintenance-113 05.30.2001 FM3069...
Page 143
: Time at which print request was received (00:00 to 23:59) For example, to produce the following readout for hospital name, print request date and time information: FUJIFILM <sp> HOSPITAL <sp> 1998.08.12 <sp> 18:30 Enter the following text: “FUJIFILM<sp>HOSPITAL<sp>%YYYY%.%MM%.%DD%<sp>%TIME%” (Note: <sp> designates a space.) Check that parameters are specified correctly, click [Apply].
Page 144
• When images of different sizes are included on an one film. • For DICOM protocol, when output image size on a film (width of image) is specified (Requested Image Size) in the image data sent from a client. 006-251-05 FN-PS551 Service Manual Maintenance-115 05.30.2001 FM3069...
SETTING - PRINT” settings of the MAINTENANCE UTILITY in the FCR 5000 series. However, three parameters (6. HN, 7. HP, and 16. AB) of them are internally processed according to data sent to the FN-PS551. For this reason, these three parameters are not shown in the service utility of the FN-PS551.
Page 147
8″×10″ images output on a 14″×17″ film (3543). Choose [Yes] to print it. • [20. Print compression rate:]: Choose [No] (default) not to print an image compression rate condition in reprint. Choose [Yes] to print it. 006-251-04 FN-PS551 Service Manual Maintenance-118 07.24.2000 FM2824...
Page 148
[Yes (“ ” or “R-reverse”)]: The letter “R” is reversed horizontally if done. [Yes (“AP” or “PA”)]: The letter “AP” or “PA” is indicated according to a camera or exposure method used (default). 006-251-04 FN-PS551 Service Manual Maintenance-119 07.24.2000 FM2824...
Page 149
0 and area 1 respectively. The size, position, and rotation is specified on the IPU 27 to 36 described later. For [IPU 27-34] From the [Annotation] window, click the [IPU 27-34] tab. → The [IPU 27-34] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-120 07.24.2000 FM2824...
Page 150
14″×17″ film (3543). It is noted that the large size is selectable from the [23. 14*17 single character size of 14*17 film] only when 14″×17″ sized image is output in an equal scaling. For other image output, the standard size is used. 006-251-04 FN-PS551 Service Manual Maintenance-121 07.24.2000 FM2824...
Page 151
[0810:]: Specify the positions and rotation of area 0 and 1 on a 8″×10″ image in four digits. The default value 0010 means that the positions of area 0 and 1 are the top left-hand corner/not rotated and the top right- hand corner/not rotated respectively. 006-251-04 FN-PS551 Service Manual Maintenance-122 07.24.2000 FM2824...
Page 152
Choose [No (FCR9000 compatible)] (default) not to move 14″×14″, 15 × 30 cm (pantomo) and 43 × 43 cm image areas to the upper part of 14″×17″ film (3543) for outputting them on it. Choose [Yes] to move them for outputting. 006-251-04 FN-PS551 Service Manual Maintenance-123 07.24.2000 FM2824...
Page 153
Maintenance-124 Maintenance 7. Service Utility BLANK PAGE 006-251-04 FN-PS551 Service Manual Maintenance-124 07.24.2000 FM2824...
Page 154
Maintenance-125 Maintenance 7. Service Utility BLANK PAGE 006-251-04 FN-PS551 Service Manual Maintenance-125 07.24.2000 FM2824...
Never use [Logging] settings in the [SERVICE UTILITY] window at installation and normal service because they are used to analyze the design and configuration of the FN-PS551 application. Only if a request is made by the Service headquarters to use the settings, make a use of them according to their instructions.
Page 156
Maintenance-127 Maintenance 7. Service Utility (Software ver. A02/A03) (Software ver. A04 or later) 006-251-04 FN-PS551 Service Manual Maintenance-127 07.24.2000 FM2824...
Page 157
Maintenance 7. Service Utility Set the following parameters. • [Logging]: Keeps a log of records of communication between FN-PS551 and devices connected to it. The default value is both off (i.e., logging off). • [network]: Records communication between FN-PS551 and network devices.
Page 158
Maintenance-129 Maintenance 7. Service Utility BLANK PAGE 006-251-04 FN-PS551 Service Manual Maintenance-129 07.24.2000 FM2824...
“ Using [Printer Property] window” of “7.4 Adding, Modifying, or Deleting a Printer [Printer]” for details. Specifying Sorting Conditions From the [SERVICE UTILITY] window, click the [Sorting] tab. → The [Sorting] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-130 07.24.2000 FM2824...
Page 160
8 characters. • FUJI Protocol (IPU Function) The contents selected by the following [CR-IPU group information] [method:] are the group information. • [by unique ID]: This parameter is disabled (not currently available). 006-251-04 FN-PS551 Service Manual Maintenance-131 07.24.2000 FM2824...
Page 161
NOTE When connecting with FM-DP L printers equipped with a sorter, sorting information transmitted from FN-PS551 should not be “01,” “02” or “03.” These numbers are duplicated and cannot be distinguished because “01,” “02” and “03” are used as the default input channel codes for FM-DP L sorting.
Page 162
Maintenance-133 Maintenance 7. Service Utility BLANK PAGE 006-251-04 FN-PS551 Service Manual Maintenance-133 07.24.2000 FM2824...
[OK]. Insert a floppy disk for saving a settings file into the disk drive. From the [File] menu, click on [Save]. → The settings file is saved onto the floppy disk. 006-251-04 FN-PS551 Service Manual Maintenance-134 07.24.2000 FM2824...
Insert the floppy disk containing the files saved into the FD drive. From the [File] menu, click on [Restore]. → The data stored in the settings file on the floppy disk are restored from it. 006-251-04 FN-PS551 Service Manual Maintenance-135 07.24.2000 FM2824...
Maintenance 7. Service Utility 7.11 Analysis Information Collection Various files necessary for analysis of defects occurring on FN-PS551 can be collected on a floppy disk using [Utility] menu in the [SERVICE UTILITY] Window. CAUTION Never use [Utility] menu at installation and normal service because they are used to analyze the design and configuration of the FN-PS551 application.
Page 166
If above mentioned step is executed without inserting floppy disk, a message prompting disk insertion appears. If this appears, insert a disk and click [OK]. When a disk becomes full, a message prompting change of disk appears. 006-251-05 FN-PS551 Service Manual Maintenance-137 05.30.2001 FM3069...
Page 167
Click [OK] and remove the floppy disk for collecting analysis information from the floppy disk drive. Click [Cancel] in dialog for selection of file to be acquired and specifications of transferred file to finish collection of analysis information. 006-251-05 FN-PS551 Service Manual Maintenance-138 05.30.2001 FM3069...
Page 168
Maintenance-139 Maintenance 7. Service Utility BLANK PAGE 006-251-04 FN-PS551 Service Manual Maintenance-139 07.24.2000 FM2824...
Install Windows NT Service Pack Install video driver Format D drive Install system utilities Set system startup latency and task bar display Install FN-PS551 application and key registry Set the FN-PS551 application display language FP4F0000.EPS 006-251-07 FN-PS551 Service Manual Maintenance-140 10.28.2002 FM3487...
If the service utility settings file has been saved onto a floppy disk during the normal operation of the FN-PS551 system prior to beginning the software reinstallation, the settings can be restored from this file.
Page 171
→ Once the system has finished reading the first disk (this takes approximately 90 seconds), the following messages [Please insert the disk labeled Windows NT Workstation Setup Disk #2 into Drive A:] appears. 006-251-06 FN-PS551 Service Manual Maintenance-142 12.18.2001 FM3271...
Page 172
→ The setup program starts and the [Welcome to Setup] screen appears about two minutes later. Press <Enter> key to continue the setup procedure. → The following screen [Setup automatically detects...] for automatic detection of mass storage devices such as CD-ROM and HDD appears. 006-251-04 FN-PS551 Service Manual Maintenance-143 07.24.2000 FM2824...
Page 173
Remove the Disk #2 and insert the “Windows NT Workstation Setup Disk #3” into the floppy disk drive and press <Enter> key. → After approximately one minute, the screen displays the storage devices detected in detail. 006-251-04 FN-PS551 Service Manual Maintenance-144 07.24.2000 FM2824...
Page 174
Insert the CD-ROM labeled “Windows NT Workstation For Distribution Only with a New PC” . Check that the CD-ROM drive access lamp goes on and out again, then press <Enter> key. → The [Windows NT Licensing Agreement] screen appears. 006-251-04 FN-PS551 Service Manual Maintenance-145 07.24.2000 FM2824...
Page 175
→ The following screen appears prompting to enter an ENTER or N for upgrading Windows NT or reinstalling this Windows NT installation. Press <N> key to install Windows NT again. → The next screen lists the detected software and hardware components. 006-251-04 FN-PS551 Service Manual Maintenance-146 07.24.2000 FM2824...
Page 176
For a hard disk drive of over 6.4 GB, partition size for “C:” is displayed as “2047 MB”, however, for partitions after “D:”, partitions and sizes displayed vary depending on the capacity of the hard disk drive. However, vacant capacity of partitions varies depending on usage status. 006-251-05 FN-PS551 Service Manual Maintenance-147 05.30.2001 FM3069...
Page 177
Check that the “C:” partition is highlighted, then press <D> key to delete the partition. → The prompt screen for deleting the partition appears. Press <Enter> key to proceed. → The execution screen for deleting the partition appears. 006-251-04 FN-PS551 Service Manual Maintenance-148 07.24.2000 FM2824...
Page 178
For a hard disk drive of over 6.4 GB, each remaining partition is moved up and displayed. Move the cursor to the “C:” partition and press <D> key (delete partition). → The execution screen for deleting the partition appears. 006-251-04 FN-PS551 Service Manual Maintenance-149 07.24.2000 FM2824...
Page 179
Check that the “Unpartitioned space” is highlighted, then press <C> key to create a partition. → The creation screen for a new partition appears. 006-251-05 FN-PS551 Service Manual Maintenance-150 05.30.2001 FM3069...
Page 180
→ The screen for selecting partitions to install reappears. The newly created partition is specified as “C: New (Unformatted) 2047 MB”. Move the cursor to “Unpartitioned space”, and press <C> key to create the partition. → The creation screen for a new partition appears. 006-251-04 FN-PS551 Service Manual Maintenance-151 07.24.2000 FM2824...
Page 181
For a hard disk drive of over 6.4 GB, partition size for “C:” is displayed as “2047 MB”, however, for “D:” partition, the values displayed differ according to the capacity of the hard disk drive. 006-251-05 FN-PS551 Service Manual Maintenance-152 05.30.2001 FM3069...
Page 182
Never choose the “D:” partition in this step. → The screen for selecting a partition format appears. (11) Move the cursor to the “Format the partition using the NTFS file system” and press <Enter> key. → The formatting process starts. 006-251-05 FN-PS551 Service Manual Maintenance-153 05.30.2001 FM3069...
Page 183
Windows NT files are to be installed appears. (12) Ensure that Windows NT files will be installed to “\WINNT”, then press <Enter> key. → The screen for selecting the type of hard disk examination appears. 006-251-04 FN-PS551 Service Manual Maintenance-154 07.24.2000 FM2824...
Page 184
CD-ROM is decompressed and copied to the hard disk. → After the files are successfully copied to the hard disk, the screen appears indicating that the Windows NT Workstation Setup has successfully completed. 006-251-04 FN-PS551 Service Manual Maintenance-155 07.24.2000 FM2824...
Page 185
It may be possible to restart (after removing the disks) by holding down <Ctrl>+<Alt>+<Delete> keys simultaneously. Try this step before beginning reinstallation. → When the system has successfully restarted, the [Insert Disk] message appears. 006-251-04 FN-PS551 Service Manual Maintenance-156 07.24.2000 FM2824...
Page 186
All settings from this point are entered using the wizard, which operates in Windows NT. This means that field entry items and multiple-option choices can be selected using the mouse. Click [Next>]. → The [Setup Options] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-157 07.24.2000 FM2824...
Page 187
Maintenance-158 Maintenance 8. Software Installation Choose [Typical] and click [Next>]. → The [Name and Organization] window appears. Type “fieldengineer” in the [Name:] field and “FUJIFILM” in the [Organization:] filed, then click [Next>]. → The [Registration] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-158...
Page 188
• The product ID shown in step (4) is an example only. It is not a valid product ID. • Press <Num Lock> key to enable the ten-key before entering numeric values. → The [Computer Name] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-159 07.24.2000 FM2824...
Page 189
Maintenance-160 Maintenance 8. Software Installation Enter a computer name (host name, e.g., FN-PS551) in the [Name] field and click [Next>]. NOTE • The computer name (host name) must be entered in single-byte alphanumeric characters. • The computer name (host name) is displayed in upper case once entered in either lower case or upper case.
Page 190
[Confirm Password:] field before proceeding to the next step. • Keep this password in secret to prevent unauthorized use. → The [Emergency Repair Disk] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-161 07.24.2000 FM2824...
Page 191
[No, do not create an emergency repair disk] and click [Next>]. → The [Window NT Components] window appears. Choose [Install the most common components (recommended)] and click [Next>]. → The [Window NT Setup] window reappears. 006-251-04 FN-PS551 Service Manual Maintenance-162 07.24.2000 FM2824...
Page 192
→ The screen for selecting the networking method to participate on a network appears. Check that [This computer will participate on a network.] is selected and that [Wired to the network:] is checked, then click [Next>]. → The screen for searching for network adapters appears. 006-251-04 FN-PS551 Service Manual Maintenance-163 07.24.2000 FM2824...
Page 193
To search for the network adapter (or Ethernet board) inside the control unit (PC). Click [Select from list...]. → The [Select Network Adapter] dialog appears. Click [Have Disk...] to install the network driver from the floppy disk. → The [Insert Disk] dialog appears. 006-251-04 FN-PS551 Service Manual Maintenance-164 07.24.2000 FM2824...
Page 194
Insert the network driver disk relevant to the control unit model into the floppy disk drive, and click [OK]. • For GX1 series: 3COM 3C90X Fast EtherLink XL NIC Drivers • For GX110 series: 3COM EtherDisk 5.04 Disk 1 → The “Select OEM Option” dialog appears. 006-251-04 FN-PS551 Service Manual Maintenance-165 07.24.2000 FM2824...
Page 195
[OK]. • For GX1 series: 3COM Fast EtherLink/Etherlink XL PCI Busmaster NIC • For GX110 series: 3COM EtherLink PCI NIC → The network adapter relevant to the control unit model is detected. 006-251-04 FN-PS551 Service Manual Maintenance-166 07.24.2000 FM2824...
Page 196
→ The screen for selecting the network protocols to use on the network appears. Make sure that the “TCP/IP protocol” is checked, then click [Next>]. → The prompt screen for installing network components appears. 006-251-04 FN-PS551 Service Manual Maintenance-167 07.24.2000 FM2824...
Page 197
‘3Com EtherDisk for EtherLink PCI NICs (Diskette 2)’ into A:” is displayed, replace with “3COM EtherDisk 5.04 Disk 2” and click [OK]. Then, [TCP/IP Set up] alert in step (10) is displayed, so carry out the procedure from step (11). 006-251-04 FN-PS551 Service Manual Maintenance-168 07.24.2000 FM2824...
Page 198
Maintenance-169 Maintenance 8. Software Installation (10) Click [Close]. → The [TCP/IP Setup] alert appears prompting to choose a Yes or No for using a DHCP server. 006-251-04 FN-PS551 Service Manual Maintenance-169 07.24.2000 FM2824...
Page 199
Adapter name displayed in [Adapter:] list of [IP Address] window varies depending on the control unit model. • For GX1 series: 3Com Fast EtherLink XL NIC (3C905B-TX) • For GX110 series: 3Com EtherLink 10/100 PCI NIC (3C905C-TX) 006-251-04 FN-PS551 Service Manual Maintenance-170 07.24.2000 FM2824...
Page 200
Enter the following information in the [IP Address:], [Subnet Mask:], and [Default Gateway:], then click [OK]. • Enter an IP address for this FN-PS551 in the [IP Address]. • If the network is using a subnet, enter mask data in the [Subnet Mask:].
Page 201
(13) Click [Next>]. → The screen for entering a computer name and workgroup appears. (14) Click [Next>] to avoid any modification to the settings. → The screen for finishing the [Windows NT Setup] wizard appears. 006-251-04 FN-PS551 Service Manual Maintenance-172 07.24.2000 FM2824...
Page 203
→ The current date and time are displayed. Check that the date and time settings are correct, then click [Close]. Readjust the settings if necessary. → The [Detected Display] message appears to confirm the video adapter. 006-251-04 FN-PS551 Service Manual Maintenance-174 07.24.2000 FM2824...
Page 204
Check that the video adapter automatically detected is [vga compatible display adapter], then click [OK]. → The [Display Properties] window appears. Click [Test]. → The [Testing Mode] information appears. 006-251-04 FN-PS551 Service Manual Maintenance-175 07.24.2000 FM2824...
Page 205
Gray Gradient FP4F0112.EPS → The following message appears prompting to choose a Yes or No for correct display of test bit map. If it is correct, click [Yes]. → The [Display Settings] message appears. 006-251-04 FN-PS551 Service Manual Maintenance-176 07.24.2000 FM2824...
Page 206
On the [Display Properties] window, click [OK]. → After compressed files are copied from the CD-ROM to the hard disk, the following message appears indicating that the Windows NT setup has been successfully completed. 006-251-04 FN-PS551 Service Manual Maintenance-177 07.24.2000 FM2824...
Page 207
Check that the operating system [Windows NT Workstation Version 4.00] is highlighted, then press <Enter> key. REFERENCE The highlighted operating system boots up automatically if <Enter> key is not pressed within 30 seconds. → The [Begin Logon] message appears. 006-251-04 FN-PS551 Service Manual Maintenance-178 07.24.2000 FM2824...
Page 208
“Administrator” for the [User name:] field should be used. → Once the computer has logged onto Windows NT, the [Welcome to Windows NT] message appears. Click [Close]. This completes the Windows NT installation process. 006-251-04 FN-PS551 Service Manual Maintenance-179 07.24.2000 FM2824...
Ensure that the install disk is write-protected (write-disabled). From the [Start] menu on the Windows NT desktop, click [Settings] and then [Control Panel]. → The [Control Panel] window appears. Double-click the [SCSI Adapters] icon. → The [SCSI Adapters] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-180 07.24.2000 FM2824...
Page 210
→ The [Remove Driver] message appears prompting to choose a Yes or No for deleting the driver. Click [Yes]. → As the installed SCSI adapter driver is deleted from the [SCSI Adapters], the field is now blank. 006-251-04 FN-PS551 Service Manual Maintenance-181 07.24.2000 FM2824...
Page 211
Maintenance-182 Maintenance 8. Software Installation Click [Add...]. → The [Install Driver] window appears. Click [Have Disk...]. → The [Install From Disk] dialog appears. 006-251-04 FN-PS551 Service Manual Maintenance-182 07.24.2000 FM2824...
Page 212
Ensure that the “Intel PIIX PCI Bus Master IDE Controller” is selected, then click [OK]. → The [System Settings Change] message appears prompting to choose a Yes or No for restarting the computer. 006-251-04 FN-PS551 Service Manual Maintenance-183 07.24.2000 FM2824...
Page 213
(11) Check that the operating system [Windows NT Workstation Version 4.00] is highlighted, then press <Enter> key. REFERENCE The highlighted operating system boots up automatically if <Enter> key is not pressed within 30 seconds. → The [Begin Logon] message appears. 006-251-04 FN-PS551 Service Manual Maintenance-184 07.24.2000 FM2824...
Page 214
[Show this Welcome Screen next time you start Windows NT] in the bottom left-hand corner of the screen, then click [Close]. (15) Close the [Control Panel] window. 006-251-04 FN-PS551 Service Manual Maintenance-185 07.24.2000 FM2824...
• Windows NT Service Pack 3 CD-ROM ........... X 1 Insert the CD-ROM labeled “Windows NT Service Pack 3” into the CD-ROM drive. → The CD-ROM loads automatically and the [Windows NT Service Pack 3-Microsoft Internet Explorer] window appears. 006-251-06 FN-PS551 Service Manual Maintenance-186 12.18.2001 FM3271...
Page 216
Maintenance-187 Maintenance 8. Software Installation Scroll the window down to display the [Install Service Pack] line. Click [Install Service Pack] . → The [Confirm File Open] alert appears. 006-251-04 FN-PS551 Service Manual Maintenance-187 07.24.2000 FM2824...
Page 217
Maintenance-188 Maintenance 8. Software Installation Click [Open]. → The [Welcome to Service Pack Setup.] wizard appears. Click [Next>]. → The [Software License Agreement] screen appears. 006-251-04 FN-PS551 Service Manual Maintenance-188 07.24.2000 FM2824...
Page 218
→ The window for selecting the type of installation desired appears. Check that the [Install the Service Pack.] option is selected, then click [Next>]. → The screen for creating an uninstall directory for the Service Pack appears. 006-251-04 FN-PS551 Service Manual Maintenance-189 07.24.2000 FM2824...
Page 219
Click [Finish]. → The status window [Copying Files...] appears indicating that files are being copied. → When the installation has been successfully completed, the following alert appears prompting to restart the system. 006-251-04 FN-PS551 Service Manual Maintenance-190 07.24.2000 FM2824...
Page 220
Maintenance-191 Maintenance 8. Software Installation (10) Remove the CD-ROM from the CD-ROM drive and click [OK]. → Once the system has restarted, the [Please select the operating system to start:] screen appears. 006-251-04 FN-PS551 Service Manual Maintenance-191 07.24.2000 FM2824...
Page 221
(11) Check that the operating system [Windows NT Workstation Version 4.00] is highlighted, then press <Enter> key. REFERENCE The highlighted operating system boots up automatically if <Enter> key is not pressed within 30 seconds. → The [Begin Logon] message appears. 006-251-04 FN-PS551 Service Manual Maintenance-192 07.24.2000 FM2824...
Page 222
Since the installation procedure requires logging on to Windows NT as the administrator, the default value “Administrator” for the [User name:] field should be used. → Once the computer has logged onto Windows NT, the Windows NT desktop appears. 006-251-04 FN-PS551 Service Manual Maintenance-193 07.24.2000 FM2824...
→ The CD-ROM loads automatically and the [Microsoft Windows NT 4.0 Service Pack 4 - Microsoft Internet Explorer] window appears. Click [Install Service Pack 4] in the [SECTION CONTENTS] field. → The [Confirm File Open] alert appears. 006-251-04 FN-PS551 Service Manual Maintenance-194 07.24.2000 FM2824...
Page 224
→ The [Windows NT Service Pack Setup] window appears. Click [Accept the License Agreement ... ] checkbox, and remove the check mark from [Backup files necessary to uninstall this Service Pack at a later time ... ] checkbox. 006-251-04 FN-PS551 Service Manual Maintenance-195 07.24.2000 FM2824...
Page 225
Maintenance-196 Maintenance 8. Software Installation Click [Install]. → The Service Pack installation process starts. → When the installation has been successfully completed, the following message appears prompting to restart the system. 006-251-04 FN-PS551 Service Manual Maintenance-196 07.24.2000 FM2824...
Page 226
Check that the operating system [Windows NT Workstation Version 4.00] is highlighted, then press <Enter> key. REFERENCE The highlighted operating system boots up automatically if <Enter> key is not pressed within 30 seconds. → The [Begin Logon] message appears. 006-251-04 FN-PS551 Service Manual Maintenance-197 07.24.2000 FM2824...
Page 227
Since the installation procedure requires logging on to Windows NT as the administrator, the default value “Administrator” for the [User name:] field should be used. → The [Windows NT Service Pack setup] information appears. 006-251-04 FN-PS551 Service Manual Maintenance-198 07.24.2000 FM2824...
Page 228
Maintenance-199 Maintenance 8. Software Installation (10) Click [No], because of the listed programs are unnecessary for the FN-PS551 application program. → Once the computer has logged onto Windows NT, the Windows NT desktop appears. 006-251-04 FN-PS551 Service Manual Maintenance-199 07.24.2000 FM2824...
Insert the CD-ROM labeled “Windows NT Service Pack 5” into the CD-ROM drive. → The CD-ROM loads automatically and the [Microsoft Windows NT 4.0 Service Pack 5 - Microsoft Internet Explorer] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-200 07.24.2000 FM2824...
Page 230
Maintenance 8. Software Installation Scroll the window down to display the [Install Service Pack 5 for Intel-based systems] line. Click [Install Service Pack 5 for Intel-based systems]. → The [Confirm File Open] alert appears. 006-251-04 FN-PS551 Service Manual Maintenance-201 07.24.2000 FM2824...
Page 231
→ The [Windows NT Service Pack Setup] window appears. Click [Accept the License Agreement ... ] checkbox, and remove the check mark from [Backup files necessary to uninstall this Service Pack at a later time ... ] checkbox. 006-251-04 FN-PS551 Service Manual Maintenance-202 07.24.2000 FM2824...
Page 232
Maintenance-203 Maintenance 8. Software Installation Click [Install]. → The Service Pack installation process starts. → When the installation has been successfully completed, the following message appears prompting to restart the system. 006-251-04 FN-PS551 Service Manual Maintenance-203 07.24.2000 FM2824...
Page 233
Check that the operating system [Windows NT Workstation Version 4.00] is highlighted, then press <Enter> key. REFERENCE The highlighted operating system boots up automatically if <Enter> key is not pressed within 30 seconds. → The [Begin Logon] message appears. 006-251-04 FN-PS551 Service Manual Maintenance-204 07.24.2000 FM2824...
Page 234
[Show this Welcome Screen next time you start Windows NT] in the bottom left-hand corner of the screen, then click [Close]. → The Windows NT desktop appears. 006-251-04 FN-PS551 Service Manual Maintenance-205 07.24.2000 FM2824...
Ensure that the install disk is write-protected (write-disabled). From the [Start] menu on the Windows NT desktop, click [Settings] and then [Control Panel]. → The [Control Panel] window appears. Double-click the [Display] icon. → The [Display Properties] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-206 05.30.2001 FM3069...
Page 236
Maintenance-207 Maintenance 8. Software Installation Click the [Settings] tab. → The [Settings] window appears. Click [Display Type...]. → The [Display Type] window appears. 006-251-04 FN-PS551 Service Manual Maintenance-207 07.24.2000 FM2824...
Page 237
Maintenance-208 Maintenance 8. Software Installation Click [Change...]. → The [Change Display] window appears. Click [Have Disk...]. → The [Install From Disk] dialog appears. 006-251-04 FN-PS551 Service Manual Maintenance-208 07.24.2000 FM2824...
Page 238
Check that the “ATI Technologies Inc. 3D RAGE PRO” display adapter is displayed and selected in the [Display:] List, and click [OK]. → The [Third-party Drivers] message appears prompting to choose a Yes or No for installing the driver. 006-251-05 FN-PS551 Service Manual Maintenance-209 05.30.2001 FM3069...
Page 239
(11) Close the [Display Type] and [Display Properties] windows by clicking [Close] on them. → The [System Settings Change] message appears prompting to choose a Yes or No for validating the system settings. 006-251-05 FN-PS551 Service Manual Maintenance-210 05.30.2001 FM3069...
Page 240
(13) Check that the operating system [Windows NT Workstation Version 4.00] is highlighted, then press <Enter> key. REFERENCE The highlighted operating system boots up automatically if <Enter> key is not pressed within 30 seconds. → The [Begin Logon] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-211 05.30.2001 FM3069...
Page 241
“Administrator” for the [User name:] field should be used. → Once the computer has logged onto Windows NT, the [Control Panel] window appears. (16) Close the [Control Panel] window. → The [Invalid Display Settings] alert appears. 006-251-05 FN-PS551 Service Manual Maintenance-212 05.30.2001 FM3069...
Page 242
Maintenance 8. Software Installation (17) Click [OK]. → The [Display Properties] window appears. (18) Click the [Settings] tab. → The [Settings] window appears. (19) Select the “True Color” option from the [Color Palette] drop-down list. 006-251-05 FN-PS551 Service Manual Maintenance-213 05.30.2001 FM3069...
Page 243
Maintenance-214 Maintenance 8. Software Installation (20) Select the “75 Hertz” option from the [Refresh Frequency] drop-down list. However, [Desktop area] remains 640 by 480 pixels. 006-251-05 FN-PS551 Service Manual Maintenance-214 05.30.2001 FM3069...
Page 244
→ The test bit map is displayed for five seconds. Then, the following message appears prompting to choose a Yes or No for the correct display. (23) Click [Yes]. (24) Click [OK] on the [Display Properties] window. → The Windows NT desktop reappears. 006-251-05 FN-PS551 Service Manual Maintenance-215 05.30.2001 FM3069...
(for a GX110 series control unit) ............. X 5 CAUTION Ensure that the install disk is write-protected (write-disabled). From the [Start] menu on the Windows NT desktop, click [Programs] and then [Windows NT Explorer]. → The [Exploring - (C:)] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-216 05.30.2001 FM3069...
Page 246
Maintenance-217 Maintenance 8. Software Installation (2) From the [View] menu on the [Exploring - (C:)] window, click [Options...]. → The [Options] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-217 05.30.2001 FM3069...
Page 247
[Hide the extensions for known file types] check box on the [View] window. Click [OK] on the [Options] window. Close the [Exploring - (C:)] window. Double-click the [My Computer] icon on the Windows NT desktop. → The [My Computer] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-218 05.30.2001 FM3069...
Page 248
→ The [New Folder] icon appears on the [(C:)] window. Change the name of the [New Folder] Icon to “Video”. (10) Insert the disk labeled “Intel 810/810e Video Driver for Windows NT 4.0 Disk 1” into the floppy disk drive. 006-251-05 FN-PS551 Service Manual Maintenance-219 05.30.2001 FM3069...
Page 249
(“Disk 2, 3, 4 and 5”) sequentially. (14) After all files are copied, close the [3 1/2 Floppy (A:)] window, and remove the disk from the floppy disk drive. 006-251-05 FN-PS551 Service Manual Maintenance-220 05.30.2001 FM3069...
Page 250
→ The any number of new files created by executes the each exe-files are added on the [Video] window. (17) Double-click the [Setup.exe] file icon from among the files created in the step (16) on the [Video] window. 006-251-05 FN-PS551 Service Manual Maintenance-221 05.30.2001 FM3069...
Page 251
Maintenance-222 Maintenance 8. Software Installation → The setup process begins, and the Setup Wizard appears. (18) Click [Next>]. → The [Software License Agreement] message appears. 006-251-05 FN-PS551 Service Manual Maintenance-222 05.30.2001 FM3069...
Page 252
(20) Make sure no disk in the respective drives of the control unit and check that the [Yes, I want to restart my computer now.] option is selected, then click [Finish]. → Once the system has restarted, the [Please select the operating system to start:] screen appears. 006-251-05 FN-PS551 Service Manual Maintenance-223 05.30.2001 FM3069...
Page 253
The highlighted operating system boots up automatically if <Enter> key is not pressed within 30 seconds. → The [Begin Logon] message appears. (22) Press <Ctrl>, <Alt> and <Delete> keys simultaneously. → The [Logon Information] dialog appears. 006-251-05 FN-PS551 Service Manual Maintenance-224 05.30.2001 FM3069...
Page 254
(25) Right-click the [Recycle Bin] icon, then click [Empty Recycle Bin] from the pop-up menu. → The [Confirm File Delete] alert appears. (26) Click [Yes]. (27) Close the [(C:)] window and the [My Computer] window. 006-251-05 FN-PS551 Service Manual Maintenance-225 05.30.2001 FM3069...
Page 255
(28) From the [Start] menu on the Windows NT desktop, click [Settings] and then [Control Panel]. → The [Control Panel] window appears. (29) Double-click the [Display] icon. → The [Display Properties] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-226 05.30.2001 FM3069...
Page 256
Maintenance-227 Maintenance 8. Software Installation (30) Click the [Settings] tab. → The [Settings] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-227 05.30.2001 FM3069...
Page 257
(31) Select the “16777216 Colors” option from the [Color Palette] drop-down list, the “75 Hertz” option from the [Refresh Frequency] drop-down list, and set the “640 by 480 pixels” for the [Desktop Area] setting. (32) Click [Test]. → The [Testing Mode] information appears. 006-251-05 FN-PS551 Service Manual Maintenance-228 05.30.2001 FM3069...
Page 258
Yes or No for the correct display. (34) Click [Yes]. (35) Click [OK] on the [Display Properties] window. → The [Control Panel] window reappears. (36) Close the [Control Panel] window. 006-251-05 FN-PS551 Service Manual Maintenance-229 05.30.2001 FM3069...
Maintenance-230 Maintenance 8. Software Installation Formatting the D Drive Double-click the [My Computer] icon on the Windows NT desktop. → The [My Computer] window appears. Right-click the [(D:)] icon. 006-251-05 FN-PS551 Service Manual Maintenance-230 05.30.2001 FM3069...
Page 260
Maintenance-231 Maintenance 8. Software Installation Choose [Format...] from the menu. → The [Format D:\] window appears. Select “NTFS” from the [File System] drop-down list. 006-251-05 FN-PS551 Service Manual Maintenance-231 05.30.2001 FM3069...
Page 261
Click [OK]. → The D: drive is reformatted (Formatting time varies depending on the capacity of the hard disk drive). → Once the formatting has been successfully completed, the following message appears. 006-251-05 FN-PS551 Service Manual Maintenance-232 05.30.2001 FM3069...
Page 262
Maintenance-233 Maintenance 8. Software Installation Click [OK]. Click [Close] on the [Format D:\] window. → The [My Computer] window reappears. Close the [My Computer] window. 006-251-05 FN-PS551 Service Manual Maintenance-233 05.30.2001 FM3069...
• For GX1 series: Dell GX1 Utilities • For GX110 series: OptiPlex System Utilities Version A13 From the [Start] menu on the Windows NT desktop, click [Run]. → The [Run] dialog appears. 006-251-05 FN-PS551 Service Manual Maintenance-234 05.30.2001 FM3069...
Page 264
Maintenance-235 Maintenance 8. Software Installation Type “A:setup” in the [Open:] and click [OK]. → The setup process begins automatically. → The Setup Wizard appears. 006-251-05 FN-PS551 Service Manual Maintenance-235 05.30.2001 FM3069...
Page 265
Make sure that the “Asset Tag Utility”, “Auto Power On Utility”, and “Auto Shutdown Service” are checked, then click [Next>]. → Once the installation has been successfully completed, the following window appears prompting to choose a Yes or No for restarting the computer. 006-251-05 FN-PS551 Service Manual Maintenance-236 05.30.2001 FM3069...
Page 266
Check that the operating system [Windows NT Workstation Version 4.00] is highlighted, then press <Enter> key. REFERENCE The highlighted operating system boots up automatically if <Enter> key is not pressed within 30 seconds. → The [Begin Logon] message appears. 006-251-05 FN-PS551 Service Manual Maintenance-237 05.30.2001 FM3069...
Page 267
Since the installation procedure requires logging on to Windows NT as the administrator, the default value “Administrator” for the [User name:] field should be used. → Once the computer has logged onto Windows NT, the Windows NT desktop appears. 006-251-05 FN-PS551 Service Manual Maintenance-238 05.30.2001 FM3069...
= on). From the [Start] menu on the Windows NT desktop, click [Settings] and then [Control Panel]. → The [Control Panel] window appears. Double-click the [System] icon. → The [System Properties] window appears. 006-251-05 FN-PS551 Service Manual Maintenance-240 05.30.2001 FM3069...
Page 270
→ The [Startup/Shutdown] window appears. Set the value for [Show list for] to “5” seconds. Click [OK] on the [System Properties] window. → The [Control Panel] window reappears. Close the [Control Panel] window. 006-251-05 FN-PS551 Service Manual Maintenance-241 05.30.2001 FM3069...
Page 271
→ The [Taskbar Properties] window appears. To cancel the current setting, click to remove the check mark from the [Always on top] check box on the [Taskbar Options] window. (10) Click [OK] on the [Taskbar Properties] window. 006-251-05 FN-PS551 Service Manual Maintenance-242 05.30.2001 FM3069...
Therefore, it is necessary to install with the key registry for IPU when using the Pattern enhancement processing for mammography option. Insert the “FN-PS551 Application CD-ROM” into the CD-ROM drive. → The CD-ROM starts up automatically and the “Welcome” screen appears. 006-251-05 FN-PS551 Service Manual Maintenance-244 05.30.2001 FM3069...
Page 274
For software ver. A05 or later, choose either [U.S.A.] or [Others] (countries other than the U.S.A.) and click [Next>]. → The installation process begins. When the installation has been successfully completed, the following screen appears. 006-251-07 FN-PS551 Service Manual Maintenance-245 10.28.2002 FM3487...
Page 275
CD-ROM. → The system restarts, and the FN-PS551 application starts up automatically. Exit from the FN-PS551 application by clicking [Exit] in the [Exit] menu on the [FN-PS551] window or clicking the close box in the top right-hand corner of the window.
Page 276
→ For instance, if the DICOM key registry is installed, the screen should appear as follows: (15) Click [OK]. (16) Exit from the FN-PS551 application by clicking [Exit] in the [Exit] menu on the [FN-PS551] window or clicking the close box in the top right-hand corner of the window.
Maintenance-248 Maintenance 8. Software Installation Setting the Language for FN-PS551 Application To change the representative language for the FN-PS551 application to one other than English (United States) that is a factory default, follow the procedure shown below. NOTE If not changing the representative language, skip this section.
Page 278
• Select from the eight languages listed above. Other languages are not supported. • If the [Set as system default locate] check box is not checked, the representative language is set back to the status which was set just before. 006-251-05 FN-PS551 Service Manual Maintenance-249 05.30.2001 FM3069...
Page 279
In this case, click [Yes] because the necessary files have already been installed and do not need to be overwritten. Then, a [Change Regional Settings] message of the step (7) is displayed, so carry out from step (8). 006-251-05 FN-PS551 Service Manual Maintenance-250 05.30.2001 FM3069...
Page 280
→ The CD-ROM is automatically started to display the [Windows NT CD-ROM] window. Click in the upper right close box of the [Windows NT CD-ROM] window to be closed. → The display returns to [Insert Disk] dialog. 006-251-06 FN-PS551 Service Manual Maintenance-251 12.18.2001 FM3271...
Page 281
Replace] message may be displayed. In this case, click [No] because the necessary files have already been installed and do not need to be overwritten. Then, a [Change Regional Settings] message is displayed. 006-251-05 FN-PS551 Service Manual Maintenance-252 05.30.2001 FM3069...
Page 282
Remove the CD-ROM from the CD-ROM drive, and choose [Yes] on the [Change Regional Settings] message. → The computer reboots and the FN-PS551 application starts up automatically. If “German (Standard)” is specified as the representative language, the following window appears.
The following will be required for the setting of the control unit (PC) to use PEI board; • “Intel Configuration Utility” disk .............. X 1 CAUTION Ensure that the disk for the setting is write-protected(write-disable). 006-251-07 FN-PS551 Service Manual Maintenance-254 10.28.2002 FM3487...
Page 284
90 seconds. Click [Add]. → The [Card Category] dialog appears. Move the cursor with the down arrow key, select [Others] at the bottom, and click [OK]. → The [Add Others Card] dialog appears. 006-251-05 FN-PS551 Service Manual Maintenance-255 05.30.2001 FM3069...
Page 285
Click the [Card Name:] field (the gray area at the right side of the title “Card Name:” at the upper left). Then, type “DXA#1” or “DXA#2” to set the first DXA board or the second DXA board, respectively. 006-251-05 FN-PS551 Service Manual Maintenance-256 05.30.2001 FM3069...
Page 286
[OK]. → Returns to the [Configure Unlisted Card] dialog. Then, the set interrupt number (“5” or “10”) appears in the [IRQ:] field. (11) Click [OK]. → The setting confirmation screen appears. 006-251-05 FN-PS551 Service Manual Maintenance-257 05.30.2001 FM3069...
Page 287
(14) Repeat the steps (4) to (13) and set the second DXA board in the similar procedure. → When the setting of the first and second DXA board are completed, the [Card Configured In System:] list of the [ISA Configuration Utility] window appears as below. 006-251-05 FN-PS551 Service Manual Maintenance-258 05.30.2001 FM3069...
Page 288
→ The ISA Configuration Utility is completed, and “C:\ICU>” appears. (18) Remove the disk from the floppy disk drive, and switch off the power to the control unit and monitor. (19) Reinstall the PEI or DXA boards in the control unit. 006-251-05 FN-PS551 Service Manual Maintenance-259 05.30.2001 FM3069...
Page 289
“Unknown Card”s appear at the time of the confirmation. Click either one of the two “Unknown Card”s, and then click the [View] ([View] in the lower menu line). → The [Card Resource Usage] dialog for the selected “Unknown Card” appears. 006-251-05 FN-PS551 Service Manual Maintenance-260 05.30.2001 FM3069...
Page 290
→ ISA Configuration Utility is completed, and “C:\ICU>” appears. (10) Remove the disk from the floppy disk drive, and switch off the power to the control unit and monitor. (11) Reinstall the PEI or DXA boards in the control unit. 006-251-05 FN-PS551 Service Manual Maintenance-261 05.30.2001 FM3069...
Select [IRQ10] using <↑> or <↓> key in the same manner, and press <Space> key to set to “Reserved”. When confirming, check that [IRQ10] is “Reserved”. NOTE All IRQs other than [IRQ5] and [IRQ10] should be set to “Available”. 006-251-07 FN-PS551 Service Manual Maintenance-262 10.28.2002 FM3487...
Page 292
→ The setup utility (BIOS) finishes and the system restarts. After restart is complete, perform shutdown procedures, and switch off the power to the control unit and monitor. (10) Reinstall the PEI boards in the control unit. 006-251-06 FN-PS551 Service Manual Maintenance-263 12.18.2001 FM3271...
If the service utility settings file has been saved onto a floppy disk during the normal operation of the FN-PS551 system prior to beginning the software reinstallation, the settings can be restored from this file.
Page 294
Refer to “8.9 Setting the Language for FN-PS551 Set FN-PS551 Application Display Language Application”. FP4F0239.EPS NOTE When installing only the application software, perform “Install FN-PS551 Application and Key Registry” and “Set FN-PS551 Application Display Language”. 006-251-06 FN-PS551 Service Manual Maintenance-265 12.18.2001 FM3271...
Perform the following step (8) if installation of Windows NT is not to be performed. When the CD-ROM is inserted, the [Windows NT CD-ROM] window appears. Click close box to close the window. Perform shutdown procedure, and switch off the power to the control unit. 006-251-06 FN-PS551 Service Manual Maintenance-266 12.18.2001 FM3271...
Page 296
On the hard disk more exhaustive secondary examination execution selection screen, press <Enter> key (Continue). (10) [This portion of Setup has completed successfully.] appears on the screen, so remove the CD-ROM from the drive, then press <Enter> key (Restart Computer). 006-251-06 FN-PS551 Service Manual Maintenance-267 12.18.2001 FM3271...
Page 297
15 characters. • The computer name (host name) must be a unique name within the installation site. If more than one FN-PS551 is used in the same installation site, each unit must be given a different name. • For Administrator Account, type the password character string “pc-ps”...
Page 298
This completes the Windows NT installation process. NOTE After installation of Windows NT has been completed, perform “ Preparation” procedures again and recover the contents of [Boot Sequence] (startup order) to the status before change. 006-251-06 FN-PS551 Service Manual Maintenance-269 12.18.2001 FM3271...
→ Installation is performed. When [InstallShield Wizard Complete] is displayed, remove the CD-ROM from the drive, and check that [Yes, I want to restart my computer now.] is selected, then click [Finish]. → The system restarts. 006-251-06 FN-PS551 Service Manual Maintenance-270 12.18.2001 FM3271...
Page 300
[Drivers] from [Topic] column. In the case of [Device Type] column, item to be selected varies according to installation of the various types of drivers afterwards, therefore follow the relevant instructions for each case. 006-251-06 FN-PS551 Service Manual Maintenance-271 12.18.2001 FM3271...
Page 301
(14) When [Remove Driver] is displayed, click [Yes], then click [Add]. (15) When the [Install Driver] screen is displayed, click [Have Disk...]. (16) When the [Install From Disk] screen is displayed, click [Browse...]. (17) When [A:\ is not accessible.] is displayed, click [Cancel]. 006-251-06 FN-PS551 Service Manual Maintenance-272 12.18.2001 FM3271...
Page 302
(22) When [Do you want to restart your computer now?] is displayed, remove the CD-ROM from the drive, then click [Yes]. (23) The system restarts, so perform the common restarting procedure for installing the various types of drivers. 006-251-06 FN-PS551 Service Manual Maintenance-273 12.18.2001 FM3271...
Page 303
(15) Check that the test bit map is displayed properly, and click [Yes] on the [Testing Mode] checking message. (16) Click [OK] on the [Display Properties] dialog, and close the [Control Panel] window. 006-251-06 FN-PS551 Service Manual Maintenance-274 12.18.2001 FM3271...
Page 304
(16) When the [Network Services:] column is displayed, click [Next]. (17) When [Windows NT is now ready to install the networking components that you selected and others required by the system.] is displayed, click [Next]. 006-251-06 FN-PS551 Service Manual Maintenance-275 12.18.2001 FM3271...
Page 305
IP Address tab, then click [OK]. • [Specify an IP address] option should be selected. • Enter an IP address for this FN-PS551 in the [IP Address]. • If the network is using a subnet, enter mask data in the [Subnet Mask].
Page 306
The [Service Control Manager] window is displayed during restart. This is always displayed after the network driver is installed. This can be resolved by installing the Service Pack again after installing all drivers. 006-251-06 FN-PS551 Service Manual Maintenance-277 12.18.2001 FM3271...
Page 307
After installation of the various types of driver software is complete, perform “Install Windows NT Service Pack 5” again according to “ Software Installation Flowchart”. Then, perform “Format D Drive”, “Set System Startup Latency and Task Bar Display”, “Install FN-PS551 Application and Key Registry”, and “Set FN-PS551 Application Display Language”. 006-251-06 FN-PS551 Service Manual Maintenance-278 12.18.2001 FM3271...
Page 308
Maintenance-279 Maintenance 10. Installing Software for GX150 Series Control Unit BLANK PAGE 006-251-06 FN-PS551 Service Manual Maintenance-279 12.18.2001 FM3271...
(Windows XP) control unit (PC) models, remove the printer interface board (PEI01A board) from the control unit before reinstallation, and attach it again after installation of FN-PS551 application and key registry is complete. If reinstallation is performed without removing it, the printer interface board will not be recognized properly and operation is not performed normally.
Page 310
Set FN-PS551 Application Display Refer to “11.6 Setting the Language for Language FN-PS551 Application” FP4F0240.EPS NOTE When reinstalling only the application software, perform “Install FN-PS551 Application and Key Registry” and “Set FN-PS551 Application Display Language”. 006-251-07 FN-PS551 Service Manual Maintenance-281 10.28.2002 FM3487...
Click [Exit] to close the window. Click the [Start] on the Windows desktop, then click [Turn off computer]. From the [Turn off computer] window, click [Turn off] to switch off the power to the control unit. 006-251-07 FN-PS551 Service Manual Maintenance-282 10.28.2002 FM3487...
Page 312
(In MB):] as the size to be set for system partition (C Partition), and press <Enter> key. NOTE The numeric figure entered here doesn't have to be exactly half. If half the value is a fractional figure, it can be rounded up or down. 006-251-07 FN-PS551 Service Manual Maintenance-283 10.28.2002 FM3487...
Page 313
15 characters. • The computer name (host name) must be a unique name within the installation site. If more than one FN-PS551 is used in the same installation site, each unit must be given a different name. • For Date and Time Settings, check that [Time Zone] and [Date & Time] are correct (readjust if they are wrong).
Page 314
(16) From the [Turn off computer] window, click [Turn off] to switch off the power to the control unit. NOTE After installation of Windows XP has been completed, perform “ Preparation” procedures again and recover the contents of [Boot Sequence](startup order) to the status before change. 006-251-07 FN-PS551 Service Manual Maintenance-285 10.28.2002 FM3487...
) on the [Dell OptiPlex ResourceCD] screen, remove the CD-ROM from the CD-ROM drive. Click [start] on the Windows desktop, then click [Turn off computer]. Click [Restart] on the [Turn off computer] window. 006-251-07 FN-PS551 Service Manual Maintenance-286 10.28.2002 FM3487...
Page 316
Select [OptiPlex GX260] from [System Model] column in [Search Criteria] items displayed on the left side of the screen. In the same manner, select [Windows XP] from [Operating System] column and select [Drivers] from [Topic] column. 006-251-07 FN-PS551 Service Manual Maintenance-287 10.28.2002 FM3487...
Page 317
“pc-ps” in the Administrator Password box, then click button. NOTE Since the installation procedure requires logging on to Windows XP as an administrator, the default value “Administrator” should be used. After this, the Windows XP desktop appears. 006-251-07 FN-PS551 Service Manual Maintenance-288 10.28.2002 FM3487...
Page 318
(11) Click [start] on the Windows desktop, then click [Control Panel]. (12) Click the [Appearance and Themes] icon on the [Control Panel] window. (13) Click the [Display] icon on the [Appearance and Themes] window. 006-251-07 FN-PS551 Service Manual Maintenance-289 10.28.2002 FM3487...
Page 319
(20) Select “(None)” from the [Screen saver] list under the [Screen Saver] tab on the [Display Properties] dialog. (21) Click [OK] on the [Display Properties] dialog, then close the [Appearance and Themes] window. 006-251-07 FN-PS551 Service Manual Maintenance-290 10.28.2002 FM3487...
Page 320
“Administrator” should be used. After this, the Windows XP desktop appears. (12) Click [start] on the Windows desktop, then click [Control Panel]. (13) Click the [Network and Internet Connections] icon on the [Control Panel] window. 006-251-07 FN-PS551 Service Manual Maintenance-291 10.28.2002 FM3487...
Page 321
Protocol (TCP/IP) Properties] dialog, then click [OK]. • [Use the following IP address] option should be selected. • Enter an IP address for this FN-PS551 in the [IP Address]. • If the network is using a subnet, enter mask data in the [Subnet Mask].
The D: drive is reformatted (Formatting time varies depending on the capacity of the hard disk drive). When a message is displayed stating that format is complete, click [OK]. Click [Close] on the [Format Local Disk (D:)] dialog to close the [My Computer] window. 006-251-07 FN-PS551 Service Manual Maintenance-293 10.28.2002 FM3487...
(10) Click [OK] on the [Taskbar and Start Menu Properties] dialog. NOTE After “Setting System Startup Latency and Task Bar Display” is complete, carry out “8.8 Installing the FN-PS551 Application and Key Registry” according to “ Software Installation Flowchart”. If the printer interface board was removed, carry out “11.5 Installing the Printer Interface Board”...
Turn on the control unit power. The FN-PS551 application starts, exit from the FN-PS551 application by clicking [Exit] on the [Exit] menu in the [FN-PS551] window or clicking the close box in the top right-hand corner of the window.
Maintenance 11. Installing Software for GX260 Series Control Unit 11.6 Setting the Language for FN-PS551 Application To change the representative language for the FN-PS551 application to one other than English (United States), which is the factory default, follow the procedure shown below. NOTE If not changing the representative language, skip this section.
Page 326
Maintenance-297 Maintenance 11. Installing Software for GX260 Series Control Unit BLANK PAGE 006-251-07 FN-PS551 Service Manual Maintenance-297 10.28.2002 FM3487...
Page 327
Installation-1 Fuji Network Print Server FN-PS551 Service Manual INSTALLATION Control Sheet Issue Date Revision Reason Pages Affected 10/30/98 New Release (FM2327) All pages 05/12/99 Revision All pages (Software ver. A02 / DICOM function expanded, etc.) (FM2442) 08/11/99 Revision 2, 11, 14, 16~19, 24~26, 28, 51 (Software ver.
Page 328
Installation-2 Installation Contents Fuji Network Print Server FN-PS551 Service Manual Installation Contents Installing Conditions ..................4 Dimensions and Weight ................ 4 System Configuration and Connection..........4 System Configuration ................. 4 Example of Connection ..............5 Temperature and Humidity ..............6 Power Supply Conditions ..............
Page 329
Checking Communication with the Client ........56 Checking Client Connections ............58 Saving Settings ....................60 Setting the Language for FN-PS551 Application .......... 62 Final Installation of FN-PS551 ................ 64 Appendix 1. Installing the Expanded Memory for the Control Unit ....66 A1.1 Installing the Expanded Memory ............
TP4B0001.EPS System Configuration and Connection System Configuration NOTE The diagram below shows an example of parts configuration appearance. Appearance varies depending on the parts model. Monitor (15-inch CRT) Mouse Control unit Keyboard FP4B0001.EPS 006-251-07 FN-PS551 Service Manual Installation-4 10.28.2002 FM3487...
DRYPIX 1000, DRYPIX 3000, DRYPIX Link NOTE Network connection based on Fuji specifications (Fuji Integrated Network Protocol (FINP)) supports software ver.A03 or later. The term “Fuji protocol” in this manual later is referred to as FINP. 006-251-07 FN-PS551 Service Manual Installation-5 10.28.2002 FM3487...
• In a location where the screen is exposed to strong light • In the vicinity of electrical equipment such as a transformer, motor, or power cable generating an AC magnetic field of 0.02 Gauss or greater 006-251-07 FN-PS551 Service Manual Installation-6 10.28.2002 FM3487...
To connect this unit to a network, prepare the necessary network parts and accessories and perform the preliminary installation work. Fuji does not provide network parts and accessories as part of its normal product range. These should be prepared taking the operating environment into consideration. 006-251-01 FN-PS551 Service Manual Installation-7 05.12.99 FM2442...
Monitor Open the carton and take out the accessories. Remove the packaging material, then take out the monitor. Other Take out the printer interface board and printer interface cable from the box. 006-251-01 FN-PS551 Service Manual Installation-8 05.12.99 FM2442...
Installation-9 Installation 2. Setting Up the Equipment Checking Contents Product Components The FN-PS551 consists of the following components. Component Name Q’ty Remarks Select either one according to Control unit DICOM protocol specifications specifications of installation site (including the monitor) TOSHIBA protocol specifications...
15-inch CRT monitor With video cable specifications, CRT monitor power cord AC 100 to 120 V and software version) FN-PS551 application software (CD-ROM) DICOM protocol key registry software(FD) Accessories (including operation manual) TP4B0006.EPS TOSHIBA Protocol Specifications Control Unit Product Part Q’ty...
Page 337
Expanded memory (128MB) This is necessary to cope with AD MEM performance deterioration when 128MB a large volume image data is received. This applies to DELL OptiPlex GX110/GX150 series control unit (PC) models. TP4B0034.EPS 006-251-07 FN-PS551 Service Manual Installation-11 10.28.2002 FM3487...
Page 338
Installation-12 Installation 2. Setting Up the Equipment DICOM Protocol Software Product Part Q’ty Remarks Code FN-PS551 application software (CD-ROM) FN-PS551 DICOM SOFT A∗∗ E (∗∗ Product code varies with DICOM protocol key registry software (FD) requirements including software version) TP4B0011.EPS...
Page 339
EU 200 V E TP4B0015.EPS Power Cords (UK specs) Product Code Part Q’ty Remarks HIC 655 Power cord (UK specs) For AC 240 V power POWER CORD supplies UK 200 V E TP4B0016.EPS 006-251-03 FN-PS551 Service Manual Installation-13 03.30.2000 FM2730...
DXA Board #2 Connected Printer Type FL-IM2636N FL-IM3543N Other Printers FL-IM3543MN DXA01A board JP1 ~ 7 JP10 ~ 13 DXA Board #1 DXA Board #2 Short JP12 and 13 Short JP5 Short JP1 FP4B0003.EPS 006-251-07 FN-PS551 Service Manual Installation-14 10.28.2002 FM3487...
Page 341
SW3 1 to 8 Switching Between A and B • A device = SW3 all ON and SW4 all devices OFF(Settings for This FN-PS551) ∗ When the printers indicated below are connected, set 1 and 2 to OFF and 3 to 8 to ON of SW3...
If a PEI01A board is to be used on the control unit with “2246” or earlier, refer to “9. Setting the Control Unit (PC) to Use PEI01A Board” in the “FN-PS551 Service Manual: MAINTENANCE” to set the control unit.
Page 343
DPSW2 1 to 8 Switching Between A and All ON ∗ • A device=DPSW2 all ON and DPSW3 all B devices OFF (Settings for this FN-PS551) ∗ When the printers indicated below are connected, set 1 and 2 to OFF and...
Cover hooks FP4B0004.EPS Remove the three cover hooks from their holes on the lower front part of the chassis. Lift the cover of the control unit up and remove it from the chassis. 006-251-06 FN-PS551 Service Manual Installation-18 12.18.2001 FM3271...
Page 345
• ISA1 and PCI2 bus slot are shared, and therefore, cannot use them at the same time. • When using DXA01A and PEI01A boards concurrently, install one board in the first slot (ISA1 or PCI2) and the other in the second slot (ISA2 or PCI1). 006-251-04 FN-PS551 Service Manual Installation-19 07.24.2000 FM2824...
Page 346
REFERENCE The illustrations of the following board installation procedure shows the case for a DELL OptiPlex GX1 series control unit model, however, the same procedure is used for a GX110 series, too. 006-251-04 FN-PS551 Service Manual Installation-20 07.24.2000 FM2824...
Page 347
E-I/F board Card edge connector Expansion card cage Riser board Expansion card connector FP4B0008.EPS Align the board retaining bracket in place, then secure it using the screw removed in step (1). 006-251-04 FN-PS551 Service Manual Installation-21 07.24.2000 FM2824...
Page 348
Gently lower the control main unit cover into its designated position on the chassis. → Press down the cover until the two cover buttons click into position. 006-251-04 FN-PS551 Service Manual Installation-22 07.24.2000 FM2824...
Install the E-I/F board in the PCI bus slot of the expansion card cage riser board (expansion slot board). • Slot layout on the riser board (expansion slot board) (For DELL OptiPlex GX150/GX260 series control unit models) PCI1 (first PEI board) PCI2 (second PEI board) FP4B0080.EPS 006-251-07 FN-PS551 Service Manual Installation-23 10.28.2002 FM3487...
Page 350
E-I/F board Card edge connector Expansion card cage Riser board Expansion card connector FP4B0082.EPS Push down the lever and fix the E-I/F board onto the expansion card cage. 006-251-07 FN-PS551 Service Manual Installation-24 10.28.2002 FM3487...
Page 351
Gently lower the control main unit cover into its designated position on the chassis. → Press down the cover until the two cover buttons click into position. 006-251-06 FN-PS551 Service Manual Installation-25 12.18.2001 FM3271...
Locater hole Locater pins (not in view) Cover button Drive bay FP4B0009.EPS Turn the control main unit upside down so that it sits on the floor stand and the drive bay faces up. 006-251-07 FN-PS551 Service Manual Installation-26 10.28.2002 FM3487...
• Layout on the control main unit rear panel (For a DELL OptiPlex GX150 series control unit model) NIC connector First PEI board Monitor connector Mouse connector Second PEI board Voltage selector switch AC power connector Keyboard connector FP4B0083.EPS 006-251-07 FN-PS551 Service Manual Installation-27 10.28.2002 FM3487...
Page 354
DELL OptiPlex GX1/GX110 series, however, a similar procedure is used for GX150/GX260 series, too. Note that layout of cable connection positions on the rear panel and voltage selector switch differs between GX1/GX110 series and GX150/GX260 series. 006-251-07 FN-PS551 Service Manual Installation-28 10.28.2002 FM3487...
Page 355
Ensure that the mouse and keyboard are connected to the appropriate ports because they have the same shaped connectors. Mouse and keyboard cannot be operated if they are incorrectly connected. Connect the CRT monitor cable connector to the monitor connector I/O port. FP4B0012.EPS 006-251-07 FN-PS551 Service Manual Installation-29 10.28.2002 FM3487...
Page 356
230 V for 200 to 240 V AC power supply). The factory default is 230 NOTE The DELL OptiPlex GX260 series control unit model does not have a voltage selector switch (Automatic detection of voltage). FP4B0014.EPS 006-251-07 FN-PS551 Service Manual Installation-30 10.28.2002 FM3487...
Page 357
CAUTION • Be sure to use the correct power cord for the power supply voltage. • If the power supply is not 100 to 120 V AC, use the optional power cord. FP4B0015.EPS 006-251-07 FN-PS551 Service Manual Installation-31 10.28.2002 FM3487...
Starting Up Turning ON the Unit Turn on the Power switch of the monitor and then that of the control unit. → After the system boots up, the FN-PS551 application starts, and the [FN-PS551] window appears. NOTE The [FN-PS551] window is pre-set at the factory to English-language display.
Page 359
Installation-33 Installation 3. Starting up Click [OK] on the [Version] message. Exit from the FN-PS551 application by clicking [Exit] on the [Exit] menu in the [FN-PS551] window or clicking the close box in the top right-hand corner of the window.
From the [Start] menu on the Windows desktop, click on [Run] . → The [Run] dialog appears. REFERENCE The following screen displays show how to install for Windows NT, however, a similar procedure is taken for Windows XP as well. 006-251-07 FN-PS551 Service Manual Installation-34 10.28.2002 FM3487...
Page 361
Remove the key registry software disk from the disk drive. From the [Start] menu on the Windows desktop, click [Program] (or [All Programs]), [Fuji Photo Film], and then [FN-PS551 Appl] to restart the FN- PS551 application. → The FN-PS551 application restarts, and the [FN-PS551] window appears.
Page 362
TOSHOBA specifications, the message should appear as follows. Click [OK] on the [Version] message. (10) Exit from the FN-PS551 application by clicking [Exit] on the [Exit] menu in the [FN-PS551] window or clicking the close box in the top right-hand corner of the window.
Page 363
Installation-37 Installation 3. Starting up BLANK PAGE 006-251-07 FN-PS551 Service Manual Installation-37 10.28.2002 FM3487...
For Windows XP, click the [Date, Time, Language, and Regional Options] icon on the [Control Panel] window. Then, click the [Date and Time] icon on the [Date, Time, Language, and Regional Options] window. → The [Date/Time Properties] dialog appears. 006-251-07 FN-PS551 Service Manual Installation-38 10.28.2002 FM3487...
Page 365
The [Date & Time] settings window should be displayed. Enter the correct current date and time in the [Date] and [Time] boxes. And then click [Apply]. Click the [Time Zone] tab. → The [Time Zone] window appears. 006-251-07 FN-PS551 Service Manual Installation-39 10.28.2002 FM3487...
Page 366
4. OS Settings Select the appropriate time zone from the drop-down list. Check that all settings are correctly made, click [Apply] and then [OK] . Close all windows being displayed on the Windows desktop. 006-251-07 FN-PS551 Service Manual Installation-40 10.28.2002 FM3487...
Double-click the [Network] icon on the [Control Panel] window. → The [Network] dialog appears. CAUTION The network settings of this FN-PS551 only apply to [Identification] and [Protocol] tabs on the [Network] dialog. For the other tabs, the default values should be used.
Page 368
Installation-42 Installation 4. OS Settings Host Name Settings Click the [Identification] tab. → The [Computer Name:] and [Workgroup:] fields appear to enter information about identification of the computer (or host) name and workgroup. 006-251-07 FN-PS551 Service Manual Installation-42 10.28.2002 FM3487...
Page 369
For other protocols, it is limited to 15 characters. • The computer (or host) name must be unique within the installation site. If more than one FN-PS551 is used in the same installation site, each unit must be given a different and unique name.
Page 370
Use [IP Address] window in the [Microsoft TCP/IP Properties] dialog to set the IP Address/Subnet Mask. For the other tabs, the default values should be used. Click the [IP Address] tab. → Setting items in which IP Address/Subnet Mask information is input are displayed. 006-251-07 FN-PS551 Service Manual Installation-44 10.28.2002 FM3487...
Page 371
If the network does not use a subnet, enter the Class C mask data (“255.255.255.0”). • Enter the IP address for the router (gateway) to which this FN-PS551 is connected in [Default Gateway:]box if image data from clients connecting to different network is received.
Page 372
[Network] dialog, then close the [Control Panel] and [My Computer] windows to finish the setting process. Click [Yes] . → The system reboots and the FN-PS551 application restarts. After that, the [FN- PS551] window appears. Exit from the FN-PS551 application by clicking [Exit] on the [Exit] menu in...
Properties] dialog to set the host name. For other setting items, the default values should be used. Click the [Computer Name] tab. → Fields appear for entering information identifying the computer (or host) name and workgroup. 006-251-07 FN-PS551 Service Manual Installation-47 10.28.2002 FM3487...
Page 374
For other protocols, it is limited to 15 characters. • The computer (or host) name must be unique within the installation site. If more than one FN-PS551 is used in the same installation site, each unit must be given a different and unique name.
Page 375
Yes or No for validation of the system settings. Click [Yes] . → The system reboots and the FN-PS551 application restarts. After that, the [FN- PS551] window appears. Exit from the FN-PS551 application by clicking [Exit] on the [Exit] menu in...
Page 376
→ The [Local Area Connection Properties] dialog appears. CAUTION Display the setting items on the [General] tab in the [Local Area Connection Properties] dialog to set the IP Address/Subnet Mask. For other setting items, the default values should be used. 006-251-07 FN-PS551 Service Manual Installation-50 10.28.2002 FM3487...
Page 377
If the network does not use a subnet, enter the Class C mask data (“255.255.255.0”). • Enter the IP address for the router (gateway) to which this FN-PS551 is connected in [Default gateway:]box if image data from clients connecting to different network is received.
Installation 5. Configuration Settings Configuration Settings Start up the Service Utility to make configuration settings of the FN-PS551 depending to the configuration of the system which the FN-PS551 is installed. NOTE Refer to “7. Ser vice Utility” in the “FN-PS551 Service Manual: MAINTENANCE”...
Programs]), [Fuji Photo Film], and then [FN-PS551Appl] to restart the FN- PS551 application. → The FN-PS551 application restarts, and the [FN-PS551] window appears. Check that the [Equip. Status] column of the [FN-PS551] window indicates the normal operation of printer. From the [Utility] menu on the menu bar, click [Test Print].
Page 381
6. Checking Operations Choose the destination printer and film size, then click [Execute] . → The [Test Print] dialog disappears. The [Job Status] column of the [FN-PS551] window indicates the progress of the test image during processing and printing one after another.
6. Checking Operations Checking Communication with the Client This test checks network transmission with all connected clients. Exit from the FN-PS551 application by clicking [Exit] on the [Exit] menu in the [FN-PS551] window or clicking the close box in the top right-hand corner of the window.
PS551 application. Confirm that the status of the printer shown in the [Equip. Status] list in the [FN-PS551] window is “Operating”, and then perform a print output from client. Check that the designated image is printed out in the correct format with no error nor image problems.
Page 385
[magnify] (for enlargement/reduction condition) and [LUT] (for tone correction condition) tabs of the [Network Clients Property] dialog. Then, restart the FN-PS551 application to print out the image from a client at the new settings, and check the printed output for image quality.
Exit the Service Utility by clicking [OK] on the [SERVICE UTILITY] window. → The Service Utility is now terminated. NOTE To change the representative language for the FN-PS551 application to other than English (United States), execute the procedure in “8. Setting the Language for FN-PS551 Application” instead of the following “...
Page 387
Choosing [Restart the computer?] or clicking the [Restart] on the [Shut Down Windows] message at step (2) will shut down and restart the computer, and start up the FN-PS551 application automatically. In this case, exit from the FN-PS551 application once,and then repeat steps (1) and (2).
8. Setting the Language for FN-PS551 Application Setting the Language for FN-PS551 Application To change the representative language for the FN-PS551 application to one other than English (United States) that is a factory default, follow the procedure shown below. NOTE •...
Page 389
Installation-63 Installation 8. Setting the Language for FN-PS551 Application BLANK PAGE 006-251-07 FN-PS551 Service Manual Installation-63 10.28.2002 FM3487...
Installation-64 Installation 9. Final Installation of FN-PS551 Final Installation of FN-PS551 Install the equipment in the final installation site. The monitor, keyboard, and mouse can be removed under the following conditions. Determine whether each of them should be used or not in consultation with the user at the installation site.
Page 391
Installation-65 Installation 9. Final Installation of FN-PS551 BLANK PAGE 006-251-07 FN-PS551 Service Manual Installation-65 10.28.2002 FM3487...
Remove the Control Main Unit Cover” procedure, either “ GX1/GX110 Series Control Unit” or “ For GX150/GX260 Series Control Unit” in “INSTALLATION 2.5 Installing the Printer Interface Board” according to the control unit (PC) model to be used. 006-251-07 FN-PS551 Service Manual Installation-66 10.28.2002 FM3487...
Page 393
• For a DELL Optiplex GX110 series control unit (There are 2 types as shown below according to the time of shipment.) Memory connector FP4B0090.EPS • For a DELL Optiplex GX150 series control unit Memory connector FP4B0091.EPS 006-251-07 FN-PS551 Service Manual Installation-67 10.28.2002 FM3487...
Page 394
Re-attach the Control Main Unit Cover” procedure, either “ For GX1/GX110 Series Control Unit” or “ For GX150/GX260 Series Control Unit” in “INSTALLATION 2.5 Installing the Printer Interface Board” according to the control unit (PC) model to be used. 006-251-07 FN-PS551 Service Manual Installation-68 10.28.2002 FM3487...
Double-click the [System] icon. → The [System Properties] dialog appears. Click the [Performance] tab. → Setting items on the [Performance] tab are displayed. Click [Change...] under [Virtual Memory]. → The [Virtual Memory] dialog appears. 006-251-07 FN-PS551 Service Manual Installation-69 10.28.2002 FM3487...
Page 396
→ A [System Settings Change] message appears. Click [Yes]. → The system reboots and the FN-PS551 application starts up automatically. Exit from the FN-PS551 application by clicking [Exit] on the [Exit] menu in the [FN-PS551] window or clicking the close box in the top right-hand corner of the window.
Page 397
Installation-71 Installation Appendix 1. Installing the Expanded Memory for the Control Unit BLANK PAGE 006-251-07 FN-PS551 Service Manual Installation-71 10.28.2002 FM3487...
Chapter 1. Network Installation Specification Chapter 1 Network Installation Specification This document represents the HI-C654/OD-F614 Network Installation Specifications (the 6th Edition Dec.20,1996). These specifications are intended for Japan; some items may not apply in other countries. 006-251-00 FN-PS551 Service Manual Appendix-4 10.30.98 FM2327...
Page 402
(12) If a network extends from one building to another, remote repeaters should be used, which should be connected via fiber optic cable. (See Fig. 3, Example of Remote Repeater Connection.) Note, however, that if the buildings share common ground (earth), local repeaters should be used. 006-251-00 FN-PS551 Service Manual Appendix-5 10.30.98 FM2327...
Page 403
Continuity will be checked between a tap portion of a transceiver and a coaxial cable. Communication Test Between Terminals or Between Coaxial Cables <Description> Bidirectional tests will be conducted between terminals or between coaxial cables to check whether communication is possible therebetween. 006-251-00 FN-PS551 Service Manual Appendix-6 10.30.98 FM2327...
Page 404
Transceiver cable: 20 m to 50 m AUI-50-5M to 50M Transceiver cable, slim: 1 m to 15 m AUI-15-1M to 15M Remote repeater Centre COM MR126F EMR304A + EOT3027 (for FC connector) or ETR506A (for ST connector) TAP4A001.EPS 006-251-00 FN-PS551 Service Manual Appendix-7 10.30.98 FM2327...
Page 405
Proper connection The number of repeaters routed is 2 for any two nodes. Improper combination The number of repeaters routed between nodes (1) and (4) is 3. Fig. 2 Example of Local Repeater Connection 006-251-00 FN-PS551 Service Manual Appendix-8 10.30.98 FM2327...
Page 406
Building A Only the SQE (heartbeat switch) of transceiver A should be Fiber optic cable turned OFF; for the other transceivers, it should be ON. Building B Fig. 3 Example of Remote Repeater Connection 006-251-00 FN-PS551 Service Manual Appendix-9 10.30.98 FM2327...
Page 407
Maximum length of twisted pair cable = 100 m. SQE switch on transceiver linking HUB and local repeater should be OFF; all others should be ON. HI-C654 HI-C654 HI-C654 HI-C654 HI-C654 OD-F614 HI-C654 HI-C654 Fig. 5 Hub Connection Setup No. 2 006-251-00 FN-PS551 Service Manual Appendix-10 10.30.98 FM2327...
Page 408
The port used for cascade connection varies between models. The Centre COM MR820TR uses port 8, while all other Allied Telsys models use port 1. All Showa Electric Wire & Cable models use port 1. 006-251-00 FN-PS551 Service Manual Appendix-11 10.30.98 FM2327...
Page 409
When above connections are completed, connect a 100 V AC power cable. After that, checking that the System FD (note that it is not the Diagnostic FD) is inserted, power ON. For more detail, refer to Chapter 2 “Installation and Connection” of the instruction manual of the router. 006-251-00 FN-PS551 Service Manual Appendix-12 10.30.98 FM2327...
Page 410
2. Backup Procedures An excerpt of “Formatting and Copying a Floppy Disk” from the instruction manual is attached hereto. A floppy disk should be formatted and copied in accordance with the procedures described. 006-251-00 FN-PS551 Service Manual Appendix-13 10.30.98 FM2327...
Page 411
3.5-inch 2HD floppy disk to be formatted is write-enabled, insert the floppy disk and then hit the [Y] and [CR] keys. DIAG>10 [CR] FD format please insert new fld and [Y/N]: Y [CR] 006-251-00 FN-PS551 Service Manual Appendix-14 10.30.98 FM2327...
Page 412
Step 3. DIAG>10 [CR] FD format please insert new fld and [Y/N]: Y [CR] ! write protected fld please insert new fld and [Y/N]: CAUTION Floppy disks other than 3.5-inch 2HD cannot be formatted. 006-251-00 FN-PS551 Service Manual Appendix-15 10.30.98 FM2327...
Page 413
Repeat Steps 3 through 5 until the writing is all completed. Then, the following message appears. >>>>> FD diskcopy ok <<<<<< DIAG> CAUTION A disk copy cannot be done on a floppy disk other than 3.5- inch 2HD, or on a write-protected or unformatted floppy disk. 006-251-00 FN-PS551 Service Manual Appendix-16 10.30.98 FM2327...
Appendix-18 Appendix Chapter 2. Service Utility-Additional Instructions Chapter 2 Service Utility-Additional Instructions 006-251-00 FN-PS551 Service Manual Appendix-18 10.30.98 FM2327...
Page 416
Note that the density cannot be increased greater than the reference gamma curve. Output QL Reference gamma curve Decreasing Max. density lowers the output QL. Input Q L FP4G0202.EPS Density Adjustment (BAR Scheme) 006-251-00 FN-PS551 Service Manual Appendix-19 10.30.98 FM2327...
Page 417
Adjust and vary the gamma curve in combination of density and contrast adjustments. Output QL Reference gamma curve Gamma curve based only on density adjustment Gamma curve after both density and contrast adjustments Input QL FP4G0204.EPS Combination of Density and Contrast Adjustments (BAR Scheme) 006-251-00 FN-PS551 Service Manual Appendix-20 10.30.98 FM2327...
Page 418
The input range for Max. density and Min. density is from 0 to 300 (corresponding to 0 to 3.00 in density), provided that Min. density < Max. density. Output density D Reference gamma curve Max. density Gamma curve after adjustment Min. density Input QL FP4G0206.EPS Overall Adjustment (SAR Scheme) 006-251-00 FN-PS551 Service Manual Appendix-21 10.30.98 FM2327...
Page 419
Gamma curve after overall adjustment contrast Increase Decrease density shift – Input QL FP4G0207.EPS Partial Adjustment (SAR Scheme) Combination of Overall and Partial Adjustments Adjust and vary the gamma curve in combination of overall and partial adjustments. 006-251-02 FN-PS551 Service Manual Appendix-22 03.30.2000 FM2730...
Page 420
Appendix-23 Appendix Chapter 2. Service Utility-Additional Instructions BLANK PAGE 006-251-02 FN-PS551 Service Manual Appendix-23 03.30.2000 FM2730...
Page 421
2.36 2.39 2.47 2.32 2.46 2.35 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 TAP4A003.EPS (Note) Diag. Unit listed in the table provides a reference for domestic use in Japan. 006-251-02 FN-PS551 Service Manual Appendix-24 03.30.2000 FM2730...
Page 422
Appendix-25 Appendix Chapter 2. Service Utility-Additional Instructions GAMMA1 GAMMA2 GAMMA4 GAMMA3 GAMMA6 GAMMA7 GAMMA8 GAMMA5 GAMMA9 GAMMA10 Gamma Curves in Each Table (BAR Scheme) 006-251-02 FN-PS551 Service Manual Appendix-25 03.30.2000 FM2730...
Page 423
2.36 2.29 2.58 2.58 2.45 2.45 2.64 2.64 2.64 2.64 2.64 2.44 2.36 2.64 2.64 2.52 2.52 TAP4A004.EPS (Note) Diag. Unit listed in the table provides a reference for domestic use in Japan. 006-251-02 FN-PS551 Service Manual Appendix-26 03.30.2000 FM2730...
Page 424
Appendix-27 Appendix Chapter 2. Service Utility-Additional Instructions GAMMA11 GAMMA12 GAMMA15 GAMMA16 GAMMA19 GAMMA20 GAMMA13 GAMMA14 GAMMA17 GAMMA18 Gamma Curves in Each Table (BAR Scheme, for TOSHIBA Modality) 006-251-02 FN-PS551 Service Manual Appendix-27 03.30.2000 FM2730...
Page 425
2.720 2.910 2.860 2.227 2.517 2.935 2.939 2.937 1023 3.000 3.000 3.000 2.313 2.800 3.000 3.000 3.000 TAP4A005.EPS (Note) Diag. Unit listed in the table provides a reference for domestic use in Japan. 006-251-02 FN-PS551 Service Manual Appendix-28 03.30.2000 FM2730...
Page 426
2.780 2.839 2.733 2.820 2.753 2.860 1023 3.000 3.000 3.000 3.000 3.000 3.000 3.000 3.000 3.000 3.000 TAP4A006.EPS (Note) Diag. Unit listed in the table provides a reference for domestic use in Japan. 006-251-02 FN-PS551 Service Manual Appendix-29 03.30.2000 FM2730...
Page 427
2.650 3.000 2.810 2.900 3.000 3.000 2.999 TAP4A007.EPS (Note) Diag. Unit listed in the table provides a reference for domestic use in Japan. Gamma 49 for Fuji QA-WS771 does not process tone correction. 006-251-03 FN-PS551 Service Manual Appendix-30 12.18.2001 FM3271...
Page 431
System ID/image number 03012246 0200 0200 1.0G#1.6-0.20 4R0.5 3V1.0 20000 *1.0*1.0 80KV10mAs xxxxx : FP4G0217.EPS The output position and display position (rotating position) on the film can be set for each area (0 and 1). 006-251-01 FN-PS551 Service Manual Appendix-34 05.12.99 FM2442...
Page 432
The definition of area position and rotation is represented as shown in the following figure. No rotation Position 1 Position 0 (top right (top left corner) corner) Image area Image area Position 2 Position 3 (bottom left (bottom right corner) corner) Position definition Rotation definition FP4G0220.EPS 006-251-01 FN-PS551 Service Manual Appendix-35 05.12.99 FM2442...
Page 433
[FC1 : ] ="0031 : 0123 1234 2345 3456 4567 5678 6789 789A" Area 0 Area 0: Position (top left-hand corner), not rotated Area 1: Position (bottom right-hand corner), 90 degree rotated FP4G0222.EPS 006-251-01 FN-PS551 Service Manual Appendix-36 05.12.99 FM2442...
Page 434
Appendix-37 Appendix Chapter 2. Service Utility-Additional Instructions BLANK PAGE 006-251-01 FN-PS551 Service Manual Appendix-37 05.12.99 FM2442...
Need help?
Do you have a question about the FN-PS551 and is the answer not in the manual?
Questions and answers