DA180 series basic AC servo drive

5.2.5 Auxiliary function mode

5.2.5.1 Functions
You can press MODE to enter the auxiliary function mode and press UP/DOWN to select auxiliary
functions.
Note: All auxiliary functions can be executed only when the servo is disabled. The auxiliary function
menu is inaccessible when the servo is enabled.
5.2.5.2 Jogging test
You can press MODE to switch to the auxiliary function mode. You can press UP/DOWN to enter the
menu and press SET to enter the jogging test screen, displaying the current rotation
speed of the motor. If you press and hold UP, the motor rotates at the specified speed
counterclockwise. It stops if you releases the key. If you press and hold DOWN, the motor rotates at
the specified speed clockwise. It stops if you releases the key.
5.2.5.3 Factory parameter restoring
You can press MODE to switch to the auxiliary function mode. You can press UP/DOWN to enter the
menu and press SET to enter the default parameter restoring screen, displaying
. Then you can press SET to restore parameters. During the restoring process, the screen
displays
clearing process for analog input 1, 2, and 3 is similar to the factory parameter restoring process.
Symbol
UP held
UP
released
. When the process ends, the screen displays
Function
Program Jog
Factory restore
Program jogging
Zero-drift clearing for analog input 1
Zero-drift clearing for analog input 2
Zero-drift clearing for analog input 3
Inertia identifying
Absolute encoder clearing
SET