6.8 PTP control (groups PtP0, PtP1, and PtP2)

Control word of
PtP0.00
segment 00
General description
Data bit
Name
Bit0–3
MODE
Bit4–7
Bit8–11
Bit12–15
Bit16–19
Bit20–23
Bit24–30
Description for MODE
Setting
0
The program stops after the current segment is executed.
1
The program jumps to the next segment after the current segment is
executed.
2
The program stops after circular execution. If CMD is 1, the circulation is
invalid.
3
The program jumps to the next segment after circular execution. If CMD is 1,
the circulation is invalid.
Description for OPT
Data bit
Name
Bit4
Bit5
OVLP
Bit6–7
Setting range
0–0x7FFFFFFF
PTP running mode.
OPT
PTP attribute.
ACC
ACC/DEC time index.
SPD
Target speed index.
DLY
Delay time index.
CYL
Number of cycles for executing the current segment.
JMP
The program jumps to the next segment.
Insertion. The current segment can suspend segments that are
INS
being executed or not executed.
Overlap. The current segment and next segment can overlap
and then be executed.
CMD
Position command type: 0 indicates incremental position while 1
indicates absolute position.
Default
0x00000000
Function
Meaning