Autotuning Control (Group P1); Inertia Identifying (Or Automatic Gain) - INVT DA180-S2R8SG0 Operation Manual

Basic ac servo drive
Table of Contents

Advertisement

DA180 series basic AC servo drive

6.2 Autotuning control (group P1)

6.2.1 Inertia identifying (or automatic gain)

P1.00
Tune inertia online
This parameter specifies whether to automatically tune inertia online and adjust the gain.
Setting
[0]
1
Data size
P1.00
Modbus address
P1.01
Inertia ratio 1
Rotation inertia ratio = Load inertia/Motor rotation inertia x 100%
If P1.01 is set correctly, the setting unit of P2.00 and P2.05 is Hz.
If P1.01 is greater than the actual value, the speed loop gain unit will increase, and if it is smaller
than the actual value, the speed loop gain unit will decrease.
If online automatic tuning is valid, the inertia ratio is updated to P1.01 in real time and written to the
EEPROM every 30 minutes.
Data size
P1.01
Modbus address
P1.02
Inertia ratio 2
The meaning of P1.02 is similar to that of P1.01.
Note: Automatic online gain adjusting is invalid for this parameter.
Data size
P1.02
Modbus address
Setting range
0–1
Online inertia identifying is invalid.
Online inertia identifying is valid.
16bit
1200, 1201
Setting range
0–10000
16bit
1202, 1203
Setting range
0–10000
16bit
1204, 1205
-102-
Default
Unit
0
-
Meaning
Data format
CANopen address
Default
Unit
250
%
Data format
CANopen address
Default
Unit
250
%
Data format
CANopen address
Function codes
Applicable
mode
P
S
T
DEC
0x2100, 0x00
Applicable
mode
P
S
T
DEC
0x2101, 0x00
Applicable
mode
P
S
T
DEC
0x2102, 0x00