DA180 series basic AC servo drive
P4.93*
Read fault records
This parameter specifies whether to enable the function of reading fault records. If the function is
enabled, the fault records specified by P4.95 are read and displayed.
Setting
[0]
1
Data size
P4.93*
Modbus address
P4.94*
Clear fault records
This parameter specifies whether to enable the function of clearing fault records. If the function is
enabled, all the fault records are cleared.
Setting
[0]
1
Data size
P4.94*
Modbus address
Fault record group
P4.95*
This parameter specifies the group number of fault records that are read.
The value 0 indicates the fault records in group 1 are read and the faults have occurred most
recently. The value 9 indicates the fault records in group 10 are read and the faults have occurred
earliest.
Data size
P4.95*
Modbus address
P4.96*
This parameter cannot be modified.
Data size
P4.96*
Modbus address
Setting range
0–1
16bit
1986, 1987
Setting range
0–1
Disable
Enable
16bit
1988, 1989
Setting range
no.
0–9
16bit
1990, 1991
Reserved
16bit
1992, 1993
Default
0
Meaning
Disable
Enable
Data format
CANopen address
Default
0
Meaning
Data format
CANopen address
Default
0
Data format
CANopen address
Setting
Default
range
-
-
Data format
CANopen address
-157-
Function codes
Applicable
Unit
mode
-
P
S
DEC
0x245D, 0x00
Applicable
Unit
mode
-
P
S
DEC
0x245E, 0x00
Applicable
Unit
mode
-
P
S
DEC
0x245F, 0x00
Applicable
Unit
mode
-
P
S
DEC
0x2460, 0x00
T
T
T
T