DA180 series basic AC servo drive
Code
Name
Er26-b
Receiving fault
Er26-c
Sending fault
Duplicate
Er26-d
synchronization signal
Er26-e Bus load ratio too high
Incorrect parameter
Er26-f
modification status
Possible cause
by the baud rate.
CAN communication is offline
or the error receiving counter
exceeds 128.
CAN communication is offline
or the error receiving counter
exceeds 128.
In the case where a slave
node
is
configured
generate
synchronization
signals,
synchronization signals are
received.
In
asynchronous
mode, the number of frames
received by a slave node
exceeds the range supported
by the baud rate.
The SDO attempts to modify
parameters in a state that
disallows modification.
-271-
1. Check communication connection.
2. Restart the servo drive.
1. Check communication connection.
2. Restart the servo drive.
to
Modify configuration so that there is
only
one
external
generation source in the entire
communication network.
working
1. Modify the time interval for the
master node to send data frames.
2. Modify the mode for the slave
node to send TPDOs.
3. Change the baud rate.
Adjust the CANopen status machine
to the Pre-OP or OP state and then
try to modify parameters.
Fault handling
Workaround
synchronization
signal