INVT DA180-S2R8SG0 Operation Manual page 103

Basic ac servo drive
Table of Contents

Advertisement

DA180 series basic AC servo drive
Torque command
P0.60
This parameter specifies the command source in torque control.
Setting
Input mode
Internally
0
specified
[1]
Analog input
2
Bus input
3
Reserved
Data size
P0.60
Modbus address
Torque command
P0.61
direction setting
This parameter specifies the method for specifying the direction in a torque command.
Setting
[0]
1
Note: 0x00F is valid when the input is a low electrical level, while 0x10F is valid when the input is a
high electrical level.
Data size
P0.61
Modbus address
Setting range
source
Specified by P0.66.
You need to set either P3.26 [Function of AI 1], P3.27
[Function of AI 2], or P3.70 [Function of AI 3] to 4 [Torque
command] and set associated parameters according to the
actual situation.
The communication bus interface can be used to receive
torque commands from the upper computer. If P4.10 is 1
[Bus input], the motor speed can be changed by P4.14 [Bus
torque command].
See the descriptions for P4.10 and P4.14.
-
1120, 1121
Setting range
The input sign of the torque command specifies the direction.
For example, Torque command input [+] indicates forward,
while [-] indicates reverse.
The torque command sign [0x00F] of the digital input function
is used to specify the direction.
1: forward
0: reverse
1122, 1123
Default
0–3
1
Description
16bit
Data format
CANopen address
Defaul
t
0–1
0
Meaning
16bit
Data format
CANopen address
-97-
Function codes
Applicable
Unit
mode
-
DEC
0x203C, 0x00
Applicable
Unit
mode
-
DEC
0x203D, 0x00
T
T

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents