DA180 series basic AC servo drive
3.2 Main circuit terminal wiring (1PH 220V)
EMI
Breaker
Filter
Emergency
stop button
Surge
absorber
Fuse
ALM
ON
OFF
MC
Motor
Yellow/
Green
RY
+
DC 24V
-
(± 10%)
ALM
+
DC 12~24V
(± 10%)
-
MC
·
Employ this emergency stop
circuit.
·
Add a surge absorber to each end
of the electromagnetic contactor
coil.
L1
·
Input voltage of power:
AC 220V(-15%)~240V(+10%)
·
L2
Keep the cable for connecting B2
and B3 in place unless an external
regenerative brake resistor is
+
used.
·
If you use an external regenerative
B2
brake resistor, remove the
connection cable between B2 and
B3 and connect the resistor as
B3
shown in the dashed box.
-
·
U
Connect the servo motor cables to
the drive output terminals U, V,
and W according to the correct
V
phase sequence. Incorrect phase
sequence may cause a drive fault.
W
·
Ground the servo drive properly.
Otherwise, electrical shocks may
be caused.
·
Prepare the 24VDC power for
CN1
electromagnetic braking by
yourself and isolate it from the
DO+
DC12~24V power for signal
control.
·
Pay attention to free-wheeling
diode connection. Reversed
DO-
polarity may cause drive damage.
-24-
Wiring instructions