Wiring Description For Cn5; Electromagnetic Brake Wiring - INVT DA180-S2R8SG0 Operation Manual

Basic ac servo drive
Table of Contents

Advertisement

DA180 series basic AC servo drive

4.5.6 Electromagnetic brake wiring

If the servo motor is used to drive the vertical shaft, the electromagnetic brake can be used to prevent
against the falling of heavy objects or keep the falling speed when the servo drive is out of power. See
the following wiring diagram for the electromagnetic brake.
Drive side
You must provide independent 24V power for the electromagnetic brake, which cannot use the
signal-control power.
RY
In the figure,
The electromagnetic brake is used for holding but not for common stop.
Though the electromagnetic brake can prevent the falling of heavy objects or keep the falling
speed, you must install an external brake device.

4.6 Wiring description for CN5

Wiring for the second-encoder terminal circuit
Note: (
RY
BRK+
9
+
-
BRK- 26
DC12–24V
external power
indicates relay coil. Pay attention to the diode direction.
Differential
command pulse
input
EXA+
EXA-
EXB+
EXB-
EXZ+
EXZ-
FG
) is shielded twisted pair.
Note: The brake winding must use independent 24V
power and cannot share the control power or relay
coil
power.
RY
Emergency-stop
RY
button
Surge
DC24V
+
power
absorber
special for
-
Fuse (5A)
brake
winding
Second encoder
3
4
10
9
14
13
CN5
-54-
Control modes
Motor
Brake
winding
EX5V
5
EX5V
EX0V
12
EX0V