Operation Manual - PoE
Quidway S6500 Series Ethernet Switches

Chapter 2 PoE PSU Supervision Configuration

2.1 Introduction to PoE PSU Supervision

The PoE-capable S6500 series can monitor the external PoE power supply units
(PSUs) through SRPUs. The external PoE PSU supervision includes:
Setting the alarm thresholds for the AC input voltages.
Setting the alarm thresholds for the DC output voltages.
Displaying unit information such as voltage and power.

2.2 AC Input Alarm Thresholds Configuration

You can set the AC input alarm thresholds for the PoE PSUs to enable the S6500
series to monitor the AC input voltages of the PSUs in real time through SRPUs.

2.2.1 AC Input Alarm Thresholds Configuration Tasks

Table 2-1 AC input alarm thresholds configuration tasks
No
1
2
3
4
Item
Enter the system view
Set the overvoltage alarm
threshold of AC input (upper
threshold) for the PoE PSUs
Set the undervoltage alarm
threshold of AC input (lower
threshold) for the PoE PSUs
Display the AC input state of
the PoE PSUs
Huawei Technologies Proprietary
Chapter 2 PoE PSU Supervision Configuration
Command
<Quidway> system-view
[Quidway]
poe-power
input-thresh
string
[Quidway]
poe-power
input-thresh
string
[Quidway]
poe-power
state
2-1
Description
Required, and
the
upper
voltage
264.0 V.
Required, and
lower
the min voltage
is 90.0 V.
Optional,
display
you
ac-input
execute
command
any view.
max
is
and
can
this
in