Operation Manual - Reliability
Quidway S6500 Series Ethernet Switches
Perform the following configuration in user view.
Table 2-2 Perform the master-slave switchover manually
Perform the master-slave switchover manually

2.2.3 Enabling/Disabling Automatic Synchronization

S6506R supports automatic synchronization. The active system stores its
configuration file and backup the configuration file to the slave system simultaneously
when the master's configuration file is modified, ensuring the consistency of the
configurations of the active system and slave system.
You can enable/disable automatic synchronize of the S6506R.
Perform the following configuration in system view.
Table 2-3 Enable/disable automatic synchronization
Enable automatic synchronization
Disable automatic synchronization
By default, the automatic synchronization is enabled.

2.2.4 Synchronizing the Configuration File of the System Manually

The system can synchronize the configuration files on the master and slave borads
automatically. If you want to synchronize them yourself, you can do it manually by
using the command below.
Perform the following configuration in user view.
Table 2-4 Synchronize the configuration file manually
Synchronize the configuration file manually
This operation can backup the configuration file to the slave board only if a slave
system is available. The configuration file will be fully copied once at every time the
operation is executed.
Operation
Operation
Operation
Huawei Technologies Proprietary
2-3
Chapter 2 HA Configuration
Command
slave switchover
Command
slave auto-update config
undo slave auto-update config
Command
slave update configuration