Quidway S6500 Series Ethernet Switches
If the configured static route is shown in the routing table, check that its hop count
is smaller than 15.
III. Troubleshoot IPX SAP
Fault 1: Unable to add static service information to the service information table.
Troubleshooting:
Use the display ipx service-table inactive command to check that the service
information is not in the inactive service information table. The entry is put there if
there is no active route to the server.
Check that the number of service information entries does not exceed the
limitation with the display ipx service-table command. IPX can support 10240
service information entries with up to 5120 service types and 5120 static service
information entries.
Fault 2: A service information entry cannot be found in the service information table.
Troubleshooting:
Check that the service information is not in the inactive service information table
with the display ipx service-table inactive command. The entry is put there if
there is no active route to the server.
Check that the VLAN interface is UP and SAP is enabled with the display ipx
interface command.
Check that the hop count of the route to the server is smaller than 16 with the
display ipx routing-table command.
Adequate memory is available for adding the service entry into the service
information table. You can try to add it as a static service entry.
Fault 3: No new dynamic service entry is found in the service information table.
Troubleshooting:
Check that:
The relevant packets are received with the debugging ipx packet and
debugging ipx sap packet verbose commands. If the packets are not received,
check that the underlying network connection is available.
IPX is enabled using the ipx enable command.
IPX is configured on the VLAN interface with the display ipx interface command.
SAP is enabled using the undo ipx sap disable command.
The number of SAP service entries is under the limit with the display ipx servers
command. IPX can support 10240 service entries with 5120 service types.
The MTU of SAP packets is not greater than the MTU at the physical layer.
Fault 4: No update packet is received on the VLAN interface.
Troubleshooting:
Check that:
Huawei Technologies Proprietary
7-17
Chapter 7 IPX Configuration