FUEL SYSTEM

HO2S REMOVAL/INSTALLATION

REMOVAL
Remove the power tilt relay case (page 10-6).
Remove the HO2S [1] from the left exhaust manifold
using a 14 mm crowfoot wrench, commercially available
tool (ANM14) [2].
INSTALLATION
Install the HO2S [1] to the left exhaust manifold and
tighten it using a 14 mm crowfoot wrench, commercially
available tool (ANM14) [2] to the specified torque.
Attach the special tool at a 90° angle to the body of the
torque wrench [3].
TORQUE: 10 N·m (1.0 kgf·m, 7 lbf·ft)
Make sure the torque wrench stays perpendicular to the
special tool. If the torque wrench is not held 90 degrees
to the tool, the torque reading will be incorrect.
Install the power tilt relay case (page 10-6).