FUEL SYSTEM
EOP SWITCH (LOW PRESSURE SIDE)
REMOVAL/INSTALLATION
Remove the cylinder head (page 14-22).
Disconnect the 1P connector [1] and remove the EOP
switch (Low pressure side) [2].
Clean the oil pressure switch threads and apply liquid
sealant
Hondabond 4, or equivalent) to the threads. Tighten the
oil pressure switch to the specified torque.
TORQUE: 8 N·m (0.82 kgf·m, 5.9 lbf·ft)
• Take care not to contaminate the switch end and oil
passage with the liquid sealant.
• Be sure to use a torque wrench to tighten the switch.
Overtightening will damage the cylinder block.
Connect the 1P connector to the EOP switch (Low
pressure side).
Install the cylinder head (page 14-24).

KNOCK SENSOR REMOVAL/

INSTALLATION

Remove the cylinder head (page 14-22).
Disconnect the 1P connector [1] from the knock sensor
[2].
Remove the knock sensor.
Tighten the knock sensor to the specified torque.
TORQUE: 32 N·m (3.3 kgf·m, 24 lbf·ft)
Connect the 1P connector to the knock sensor.
Install the cylinder head (page 14-24).